179984 Database Inconsistency Failure
Symptom
Database Inconsistency Failure: Continue and call service for repair is displayed on the image monitor. This issue may occur during "Start" of an exam or during an exam. It occures when a file corruption has occurred in the DL database. This is a warning to the customer that file corruption has occurredon the image disk and a corrupt sequence may not network or display properly. Xray is not inhibited. Database Inconsistency Failure: Continue and call service for repair is displayed on the image monitor. This issue may occur during "Start" of an exam or during an exam. It occures when a file corruption has occurred in the DL database. Database inconsistency failure and a Debug text of Check And Repair Requested at Browser initialization. When the customer boots the system, the image monitor displays Database inconsistency failure: Continue and call service for repair. This is a warning to the customer that file corruption has occurredon the image disk and a corrupt sequence may not network or display properly. Xray is not inhibited.
Error message
1600033 A possible hardware error has been detected by the IP disks chain. MSA_CHECK_CONDITION: Check Condition (see sense data) 1600033 A possible hardware error has been detected by the IP disks chain AR XRImProc acquisition Component(s)_DL_Image_Disk 1 1 MCOS error: code=-32963064 => MSA_CHECK_CONDITION: Check Condition (see sense data) driver.c 2280 1600017 IH XRImProc An asynchronous error has been detected by the IP, HANG CPU - STOP RUN NOTIFICATION NOT RECEIVED CeId = 3 1600017 IH XRImProc An asynchronous error has been detected by the IP, reset req. Debug: class IpFluoroWritePacketOpIP HANG CPU - STOP RUN NOTIFICATION NOT RECEIVED - CeId = 3 - start = xxxxxxxxxxx - stop = xxxxxxxxxxx - cumulative = xxxxxxxxxxx - maxValue = xxxxxxxxxxx
Applies to
- Models
- Innova
- Product
- Innova 2000 Innova 2000 systems Innova 2000 systems Innova X100 Monoplane Innova X100 Monoplane from product name Innova 2100, 3100 and 4100 Innova X100 Monoplane Innova 2100, 3100 and 4100
- Area
- X-ray Vascular
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray Vascular issues
- The Worklist does not refresh on the system when performing a query.
- Innova System boot failure
- INX1X; Message Limit switch engaged; LP4 Lateral Detector lift will not move after going to max SID using the Emergency Backout button on the lift cover because the lift hit maximum (Max) SID limit sw…
- Firewall is broadcasting DHCP addresses
- Cooling Failure; Shut System down and call Service is displayed on the Innova Image monitor
- No gantry motion is reported by the customer.