Pular para o conteúdo principal
GE Healthcare · X-ray VascularInnovaAdvantx300493005330050

Advantx displays reset on console and xray is inhibited

Symptom

Advantx displays reset on console and xray is inhibited

Error message

30049/42E5, 30053/42E9, 30050/42E6, Power unit tube spit recovery. KV failure with Grid pulse Feedback not detected. 30049: DO: ECM: Power Unit KV Failure: 42E5 30053: DO: ECM: Power Unit KV Imbalance Fault 42E9 30050: DO: ECM: Power Unit Thyristor failure 42E6 See LD for complete error. 30049: DO: ECM: Power Unit KV Failure: 42E5: Debug: fct-status=0 hw-status=35 pos-error=42e5 usr-status=0 HWStatus=0035 User=0000 0000 42E5 30053: DO: ECM: Power Unit KV Imbalance Fault 42E9: Debug: fct-status=0 hw-status=39 pos-error=42e9 usr-status=0 HWStatus=0039 User=0000 0000 42E9 30050: DO: ECM: Power Unit Thyristor failure 42E6: Debug: fct-status=0 hw-status=36 pos-error=42e6 usr-status=0 HWStatus=0036 User=0000 0000 42E6 Intermittent 42E6 errors will usually be followed by 4260 (Generator in reset state) and sometimes 422D (Generator in reset state - prep and expose switch ignored). Error 42BE (and sometimes 42BF) will occur if an exposure is attempted after the fuses have blown.

30049, error Text = POWER UNIT : KV FAILURE, debug Text = HWStatus=0035 User=0000 0000 42E5, recovery Class = DO, major Function /= ECM System impact: None. 1 tube spit that can be heard by customer. Displayed mes

Applies to

Models
Innova, Advantx
Product
Innova 2000 Innova 2000 systems Innova 2000 systems
Component
X-ray tube MX150V5 TH.13 X-ray tube MX150V5 TH.13 RELOAD: Part #: 2149522-2 *** OLC 2ND OPINION PART *** Part #: 2149522-2 Part Type: GP TUBES Part Weight: -5999940.00 LBR Repairable: No Returnable: Yes Hazardous Material: N Description: MX150V5 TH.13 RELOAD FRU: Yes Status: Orderable Comments: If no stock on this pn you can order pn D2712C (fru up) SPelletier 23 january 2006 *** OLC 2ND OPINION PART *** Need to check Grid Tank / Cables / and Run-in & Stability process in case of noise. If replacing the tube due to arcing or tube spits the microgrid tank (2127280-2) should be replaced also per SN4621. Other FRUs: 40 & 70 degree sensors 2133581-2, Quick Disconnects Female 2343093, Male 2343091
Area
X-ray Vascular

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare X-ray Vascular issues