BrightSpeed Select, Delight Select or MERI Select
Symptom
Pink Pop Up Message saying The system has been configured for a Performix Tube for 30 days. See Long Description for full text of message. Pink Pop Up Message saying The system has been configured for a Performix Tube for 30 days Tube type at the end of the first sentence in message below can vary. The system has been configured to recognize a GE Medical Systems Tube. A 30 day period from the date of tube installation has been granted to allow time to manually verify the tube identity. Please call GE Medical Systems to dispatch a Field Service Engineer (FSE) to verify the tube configuration. Please allow a minimum of 10 days for the FSE to schedule verification. Verification should take no more than 30 minutes. If a GE Medical Systems FSE does not verify the tube identity within %s days, the system will revert to an "unrecognized tube" status, resulting in the following: - GE Medical Systems cannot assure that the system performance will conform to specifications. - Advisory messages will be posted to the operator about an unrecognized tube during system startup, during tube warm-up, during Fast Calibration, and in the dose report.
Error message
Error: 244646 the system will revert to "unrecognized tube" status See long description for full error Tue Apr 10 21:07:28 2007 Error: 244646 Host: ct02 Process: fwmgr File: tubeApprovalPopupMgr.cxx Line: 259 Tube verification reminder: If a GE Medical Systems FSE does not verify the tube identity within 30 days, the system will revert to an unrecognized tube" status.
Applies to
- Models
- BrightSpeed, VCT
- Product
- BrightSpeed Select, Delight Select or MERI Select Elite-16, Edge-8, Excel-4 HP_S_G16_G_HLT HP_S_G8_G_HLT HP_S_G4_G_HLT BrightSpeed Select or Delight Select (Hivalue Lite) 4/8/16 Slice Scanner BrightSpeed Delight Select Systems started to ship in first Quarter or 2009 with AIO (All in One) Console. AIO console uses HP8400 and NO DARC or IG's. Recon time is 6 FPS. If customer orders Fluoro option system requires one IG. The 16 FPS Upgrade in Not Available for Select systems. BrightSpeed Meri Select Systems ( Pancake Das ) started to ship in 3rd quarter of 2010, 4/8/16 Slice Scanner HiValue 16 Lite −−> BrightSpeed Elite Select HiValue 8 Lite−−> BrightSpeed Edge Select HiValue 4 Lite−−> BrightSpeed Excel Select BrightSpeed Select Scope: - 3.5MHu Solarix tube - JEDI 60 dc Lite - Modified NP Table Key Features: - 16x0.625mm(16x1.25) for Lite 16 - 8x1.25/8x2.5mm for Lite 4/8 - Rotation Speed: 0.8 s - Gantry: 2040mm width, 70cm Bore - Table: 1337@ISO-140mm scannable range - Recon: 3fps (w/o IG @ 2G Memory(4/8), 4G Memory(16)), optional: 6fps(w/ 1IG ) - Power: 42KW JEDI power See the attached Service Intro Planner for details Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required