GE Healthcare · X-ray VascularInnova105004210502611050260105016710506071050103
Innova; Table and Gantry will not move by any control.
Symptom
Innova; Table and Gantry will not move by any control. Table and Gantry cannot Move, TSSC prd display: BD Innova; Table and Gantry will not move by any control.
Error message
1050042 Larm AXIS POWER No Motion Larm AXIS POWER 1 0 - Power input from K3 problem (prd: BD) 1050042 Larm AXIS POWER WR GantryAxis No Motion Larm AXIS POWER 1 0 - Power input from K3 problem (prd: BD) INX100: 1050261 FRT PIVOT AXIS SWITCH ENGAGED (PRD BC) error code 1050261 FRT PIVOT AXIS SWITCH ENGAGED WR GantryAxis No Motion PIVOT_Limit_Switch 1 0 - Limit switch 2 problem (prd: BC) Z:/heroic/prd_task.c 638 MCB prd code BCH is displayed on the MCB is displayed in the error log. The Pivot MCB has a PRD code of BC displayed on it. INX100: 1050261 FRT PIVOT AXIS SWITCH ENGAGED (PRD BC) error code 1050261 FRT PIVOT AXIS SWITCH ENGAGED WR GantryAxis No Motion PIVOT_Limit_Switch 1 0 - Limit switch 2 problem (prd: BC) Z:/heroic/prd_task.c 638 MCB prd code BCH is displayed on the MCB is displayed in the error log. The Pivot MCB has a PRD code of BC displayed on it. 1050261: Front: FRT PIVOT AXIS SWITCH ENGAGED; Debug Text: - Extra course switch engaged or 24V failure (4AB6) 1050260 FRT LARM AXIS SWITCH ENGAGED -Limit switch 2 problem (prd: BC) 1050260 FRT LARM AXIS SWITCH ENGAGED WR GantryAxis No Motion LARM_Limit_Switch 1 0 - Limit switch 2 problem (prd: BC) Z:/heroic/prd_task.c 638
Applies to
- Models
- Innova
- Product
- Innova X1 X1 Biplane Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System Innova X100 Monoplane Innova X100 Monoplane from product name Innova 2100, 3100 and 4100 Innova X100 Monoplane Innova 2100, 3100 and 4100 Innova 2000 Innova 2000 systems Innova 2000 systems
- Component
- Positioner Gantry Positioner Gantry Positioner Gantry
- Area
- X-ray Vascular
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray Vascular issues
- The Worklist does not refresh on the system when performing a query.
- Innova System boot failure
- INX1X; Message Limit switch engaged; LP4 Lateral Detector lift will not move after going to max SID using the Emergency Backout button on the lift cover because the lift hit maximum (Max) SID limit sw…
- Firewall is broadcasting DHCP addresses
- Cooling Failure; Shut System down and call Service is displayed on the Innova Image monitor
- No gantry motion is reported by the customer.