The Advantx console displays 600E Recommended X–ray tube Preventive Maintenance.
Symptom
The Advantx console displays 600E Recommended X–ray tube Preventive Maintenance. Call service and continue; on power up or boot. The Advantx console displays 600E Recommended X–ray tube Preventive Maintenance. Call service and continue on power up or boot. This error is reported at warm start if the values in NV_G_fil_correction_X have increased from their initial values in NV_G_fil_correction_at_cal_X by more than 3B$0000H. This error is for display only, no corrective action is taken in the software. In a system that is operating normally, this error will appear after an extended period of time where the filaments have aged and the filament correction value has been increased to compensate for the aging effects.
Error message
ADX: 600E HW: XXXX User: XXXX INNOVA ERROR 70002 ADX: 600E HW: XXXX User: XXXX See Long description for User codes. INNOVA ERROR 70002 ADX: 600E HW: XXXX User: XXXX If the error is intermittent, or frequent, suspect arcing in the system to be driving the filament aging values erratically, causing the issue. Perform high Voltage testing on the system to determine if that is the root cause of the issue. The USER field of the error block contains the Tube, Focal Spot and Function in the following manner: USER error status = TFnI , where: T = tube number F = focal spot (0 = small, 1 = medium, 2 = large) n = 0 I = function 0 = rad 1 = Cine 2 = Conventional Fluoro 3 = Progressive Fluoro
Applies to
- Models
- Advantx, Innova
- Product
- Advantx, LFX Advantx product line LFX Advantx product line
- Component
- X-ray tube MX150V5 TH.13 X-ray tube MX150V5 TH.13 RELOAD: Part #: 2149522-2 *** OLC 2ND OPINION PART *** Part #: 2149522-2 Part Type: GP TUBES Part Weight: -5999940.00 LBR Repairable: No Returnable: Yes Hazardous Material: N Description: MX150V5 TH.13 RELOAD FRU: Yes Status: Orderable Comments: If no stock on this pn you can order pn D2712C (fru up) SPelletier 23 january 2006 *** OLC 2ND OPINION PART *** Need to check Grid Tank / Cables / and Run-in & Stability process in case of noise. If replacing the tube due to arcing or tube spits the microgrid tank (2127280-2) should be replaced also per SN4621. Other FRUs: 40 & 70 degree sensors 2133581-2, Quick Disconnects Female 2343093, Male 2343091
- Area
- X-ray Vascular
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray Vascular issues
- The Worklist does not refresh on the system when performing a query.
- Innova System boot failure
- INX1X; Message Limit switch engaged; LP4 Lateral Detector lift will not move after going to max SID using the Emergency Backout button on the lift cover because the lift hit maximum (Max) SID limit sw…
- Firewall is broadcasting DHCP addresses
- Cooling Failure; Shut System down and call Service is displayed on the Innova Image monitor
- No gantry motion is reported by the customer.