Message "UPS transition error, only fluoro is available.
Symptom
Message "UPS transition error, only fluoro is available. Call service" is displayed after system boot Message "UPS transition error, only fluoro is available. Call service" is displayed after system boot. Innova system has the Fluoro UPS option which has been installed and configured as per installation job card. When Power Mains is present and fluoro UPS option configured in SUIF/Options, the message is displayed after boot up (It should not because Mains is ON). This message is not displayed if fluoro option is not configured in SUIF/Options. Message "UPS transition error, only fluoro is available. Call service" is displayed on DL In Room Monitor after system boot. Innova system has the Fluoro UPS option which has been installed and configured as per installation job card. When Power Mains is present and fluoro UPS option configured in SUIF/Options, the message is displayed after boot up (It should not because Mains is ON). This message is not displayed if fluoro option is not configured in SUIF/Options.
Error message
410017 UPS power switch failure on switch status UPS. In the case the timer PowerSwitchCmd expired or If SWITCH_STATUS indicates system is ON_UPS and POWER_SWITCH_COMMAND is ON_MAIN, record shall be inhibited with UPS_POWER_SWITCH_FAILURE inhibit. 410017 UPS power switch failure on switch status UPS. In the case the timer PowerSwitchCmd expired or If SWITCH_STATUS indicates system is ON_UPS and POWER_SWITCH_COMMAND is ON_MAIN, record shall be inhibited with UPS_POWER_SWITCH_FAILURE inhibit.
Applies to
- Models
- Innova
- Product
- Innova X100 Monoplane Innova X100 Monoplane from product name Innova 2100, 3100 and 4100 Innova X100 Monoplane Innova 2100, 3100 and 4100
- Area
- X-ray Vascular
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray Vascular issues
- The Worklist does not refresh on the system when performing a query.
- Innova System boot failure
- INX1X; Message Limit switch engaged; LP4 Lateral Detector lift will not move after going to max SID using the Emergency Backout button on the lift cover because the lift hit maximum (Max) SID limit sw…
- Firewall is broadcasting DHCP addresses
- Cooling Failure; Shut System down and call Service is displayed on the Innova Image monitor
- No gantry motion is reported by the customer.