GE Healthcare · X-ray VascularInnova10000146001057001051000101
Xray not Available - Reset System; If Problem Persists Call Service is displayed on the Image Monitor.
Symptom
Xray not Available - Reset System; If Problem Persists Call Service is displayed on the Image Monitor. Xray not Available - Reset System; If Problem Persists Call Service is displayed on the Monitor.
Error message
error Code = 1000014, error Text = SID_SSD out of range, debug Text = SID out of range, recovery Class = IH, major Function /= XRImChainPos System impact: X-ray unavailable. Displayed message : "SID pb, use lift orange button to move detector to highest position". Note: This error is also logged when the positioner is resetted. error Code = 600105 (FRT) and/or 700105 (LAT), error Text = ARCNET Communication Failure , debug Text /= Null , recovery Class = IH, major Function /= XRBeamForm Error Code = 600105 (FRT) and/or 700105 (LAT), error Text = ARCNET Communication Failure , debug Text /= Null , recovery Class = IH, major Function /= XRBeamForm System impact: X-ray and Gantry motion unavailable. INX100: 1000101 AR XRImChainPos Software recoverable Problem Debug: [XRImChainPos::logTifError] code=18 debugText=(GebDriver local error code = 5 , error number = 0) 1000101 AR XRImChainPos Software recoverable Problem Debug: [XRImChainPos::logTifError] code=18 debugText=(GebDriver local error code = 5 , error number = 0)
Applies to
- Models
- Innova
- Product
- Innova 2000 Innova 2000 systems Innova 2000 systems Innova X100 Monoplane Innova X100 Monoplane from product name Innova 2100, 3100 and 4100 Innova X100 Monoplane Innova 2100, 3100 and 4100 Innova X1 X1 Biplane Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System
- Component
- Positioner Gantry Positioner Gantry Positioner Gantry
- Area
- X-ray Vascular
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray Vascular issues
- The Worklist does not refresh on the system when performing a query.
- Innova System boot failure
- INX1X; Message Limit switch engaged; LP4 Lateral Detector lift will not move after going to max SID using the Emergency Backout button on the lift cover because the lift hit maximum (Max) SID limit sw…
- Firewall is broadcasting DHCP addresses
- Cooling Failure; Shut System down and call Service is displayed on the Innova Image monitor
- No gantry motion is reported by the customer.