GE Healthcare · MR223685422375372237538
R2 Not Updating in Manual Prescan MPS.
Symptom
R2 Not Updating in Manual Prescan MPS The numerical value in the upper-right corner of MPS always displays zero for R2 but R1 functions normally. FID is a flatline void of any noise or signal. R1's value will change when TG is increased or decreased indicating transmit power is present and R1 is making the calculation.
Error message
2236854 A data error occurred during a MEDCAM to CAP blockmode VSB data transfer. Wed Jan 12 17:18:42 2011 Error: 2236854 Host: MRS2-OC0 Process: diags File: diagsMain.m Line: 1855ISE DP: VSB Bus Test Failure.A data error occurred during a MEDCAM to CAP blockmode VSB data transfer.The data was verified by the CAP.CAP addr: 80103000HVME addr: 405b4000HData exp: 00005442HData read: 04005442HFRU(s): CERD Digital Bd, MEDCAM 2237537 A data error occurred during a CAP to MEDCAM blockmode data transfer Wed Jan 12 17:18:42 2011 Error: 2237537 Host: MRS2-OC0 Process: diags File: diagsMain.m Line: 1855ISE DP: VSB Bus Test Failure.A data error occurred during a CAP to MEDCAM blockmode data transferover the VSB bus. The data was verified by the TPS CPU.VME addr: 405b4000HData exp: 00005442H Data read: ffffffffH FRU(s): CERD Digital Board, MEDCAM 2237538 A data error occurred during a CAP to MEDCAM blockmode memory fill over Wed Jan 12 17:18:42 2011 Error: 2237538 Host: MRS2-OC0 Process: diags File: diagsMain.m Line: 1855ISE DP: VSB Bus Test Failure.A data error occurred during a CAP to MEDCAM blockmode memory fill over the VSB bus. The data was verified by the TPS CPU.VME addr: 405ac000HData
Applies to
- Product
- Profile 2 SPARC20 with AN8290Y gradients
- Software
- Profile Contour 7.67 Applies to Profile1 through 4 and Contour1 through 4. This is the last revision of software for this product line. Requires 7.66 LFC. 7.67 is a patch.
- Component
- 2160818-7 IPGII Board SUN STYLE FRONT PANEL See Long Description IPG2 Board 2160818-7 FEMC Part Description: IPGII SUN STYLE FRONT PANEL
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- Running grafidy3, and find there are spikes on the waveforms in the manual prescan display, both windows.
- OrthoMRI Network cable is unplugged
- TPS/MGD fails to download or reset. mgd_term windows fail to mount file system.
- CWA ID100060 Unable To Film.
- Fails to Scan with TORSO Coil.
- The Carriage Fails to Advance to Latch to the Table and to Retract When it is Raised, Undocked or Lowered.