Pular para o conteúdo principal
GE Healthcare · CTBrightSpeedVCT200109106

BrightSpeed HPower, Delight, Velocity or MERI HPower

Symptom

Scanning aborted with out of memory for scan files. Scanning aborted with out of memory for scan files

Error message

Error: 200109106 The current prescription requires XX number of scan keys for scan files. See long description for details Tue Aug 14 16:28:25 2007 Error: 200109106 Host: cccgvct1 Process: scanRx File: SIRx.cxx Line: 6802 Function: Data Acquisition : OC Processing The current prescription requires XX number of scan keys for scan files. The system currently has 0 scan keys available. You must change the prescription, wait for the current recons to complete, or release scan files to continue.

Applies to

Models
BrightSpeed, VCT
Product
BrightSpeed HPower, Delight, Velocity or MERI HPower HP_P_G4_G_HPT Excel HP_P_G8_G_HPT Edge HP_P_G16_G_HPT Elite HP_P_G16_G_GMV Elite HP_P_P16_G_GMV Elite HP_P_M16_G_HPT BrightSpeed Method of remote software hardware identification check_config swhwinfo List of Supported Console Types : HP_P_G16_ G _HPT Note: G could be GRE, AIO or TIO - check with: cat /usr/g/config/INFO | grep CONSOLETYPE GOC4 AIO TIO List of softwares the product can run: 08BW20.1 07MW11.10 08BW44.1 ( Delight ) 09HW30.4 ( Velocity ) 09BW35.11 ( MERI - Pancake DAS ) FAQ's 1. All BrightSpeed Power Systems use the Performix tube D3186T HP_P_G4_G_HPT (Excel - H-Power Table) HP_P_G8_G_HPT (Edge -H-Power Table ) HP_P_G16_G_HPT (Elite -H-Power Table ) HP_P_G16_G_GMV (Elite -Global Table Mid Value - modified GT1700 no IMS ) Note: G could be GRE, AIO or TIO (check with: cat /usr/g/config/INFO | grep CONSOLETYPE ) BrightSpeed Elite Power Systems will only be sold as Velocity System starting in 2Q/2010. Delight Elite Power being phased out 1Q/2010 BrightSpeed Power 4 & 8 slice systems have been discontinued due to restructuring of the product lineup. Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Software
09HW30.4 For BrightSpeed Velocity See long Description 09HW30.4 For BrightSpeed Velocity {ctuser@ct01}[2] check_config sw_hw_string: 09HW30.4.HP_P_G16_G_GMV Software Collector Version 09HW30.4 p/n 5357076 5352829 - Class C (Tab# 182) 5357125 - Class M (Tab# 182)
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare CT issues