GE Healthcare · MRSignaExcite222569922257372225739222551222256932225550
Unable to Scan with Power Monitor and MDS Link Faults due to System Support Module SSM.
Symptom
Unable to Scan with Power Monitor and MDS Link Faults
Error message
2225699 MDS link failure. An MDS device failed to respond to IPG on a 2nd try. If the link is broken, a separate error message will be logged. If not, a spurious error occurred. Timer: 509 MDS header: 0x11 -(00/10 = Grad, 01/11 = RF Cab) MDS opcode: 0x0B 2225699 lx-mr NSP HPC_PORT_ID:spi_mds 509 MDS link failure. An MDS device failed to respond to IPG on a 2nd try. If the link is broken, a separate error message will be logged. If not, a spurious error occurred. Timer: 509 MDS header: 0x11 -(00/10 = Grad, 01/11 = RF Cab) MDS opcode: 0x0B 2225737 Power Monitor 1 Fault. RF Transmit power has reached safety limit allowed for scan parameters and patient weight. Thu Mar 7 16:22:41 2002 2225737 2 lx-mr NSP HPC_PORT_ID:spi_pm_log_error 100 Power Monitor 1 Fault. RF Transmit power has reached safety limit allowed for scan parameters and patient weight. Check patient weight entered. amplitude: 40 pulse width: 33 duty cycle: 03 Fault in head amplitude. If you need to confirm the source of the fault, reset the power monitor and repeat the scan. This could also occur when power cycling SSM.> Thu Mar 7 16:22:41 2002 2225737 2 lx-mr NSP HPC_PORT_ID:spi_pm_log_error 100 Power Monitor 1 Fault.RF
Applies to
- Models
- Signa, Excite
- Product
- Signa LX Signa LX Product can be used with 8.x and 9.x systems.
- Software
- 9.1 For Signa LX product only
- Component
- SecondOpinion System Support Module 2160200-43 See comments in resolution concept for second opinion requirements before ordering this part. FE replaced SSM which is now a FRU Part #: 2160200-43 Part Type: GP REPAIRABLES Part Weight: 48.50 LBR Repairable: Yes Returnable: Yes Hazardous Material: N Description: ERBTEC #550020 SYSTEM SUPPORT MODULE FRU: Yes Status: Orderable ICV/Transfer Price: 5684.00 USD /Each List Price: 36215.22 USD /EACH See comments in resolution concept for second opinion requirements before ordering this part. FE replaced SSM which is now a FRU Part #: 2160200-43 Part Type: GP REPAIRABLES Part Weight: 48.50 LBR Repairable: Yes Returnable: Yes Hazardous Material: N Description: ERBTEC #550020 SYSTEM SUPPORT MODULE FRU: Yes Status: Orderable ICV/Transfer Price: 5684.00 USD /Each List Price: 36215.22 USD /EACH
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- Running grafidy3, and find there are spikes on the waveforms in the manual prescan display, both windows.
- TPS/MGD fails to download or reset. mgd_term windows fail to mount file system.
- Fails to Scan with TORSO Coil.
- The Carriage Fails to Advance to Latch to the Table and to Retract When it is Raised, Undocked or Lowered.
- AE title has changed on destination host.
- Unable to Load Applications Software during restoreinfo Due to Corrupt saveinfo Disk.