GE Healthcare · MRDiscoveryExciteOptima227002822700312270023
CWA System Software suddenly locked up.
Symptom
System Software suddenly locked up System Software suddenly locked up.
Error message
2270028 VRF - Error bit(s) activated in RRX Status Register 2 (0x00F8 Error: 2270028 Host: MOI_MR Process: LxMxConsumer File: VrfTrace.cpp Line: 80 Server Name: ADS1 VRF - Error bit(s) activated in RRX Status Register 2 (0x00F8). The VRF is located at ICN1(ICN2), if ADS(ADS1) reports this error. VRF ID: 0x0 RRX Status Register 2: 0x8000000000000000 2270031 RRX to VRF fiber link ERROR. Check the dual fiber optic cable connection from the RRX to the VRF. Nov 12 Fri 16:13:07 2270031 LxMxConsumer VrfTrace.cpp 80 Server Name: ADS1 RRX to VRF fiber link ERROR. Check the dual fiber optic cable connection from the RRX to the VRF. Check power to RRX module. The VRF is located at ICN1(ICN2), if ADS(ADS1) reports this error. VRF Register: 0x30 Descriptions: 0x131000000000-> 2270023 VRF - Error bit(s) activated in Link Control Status Register (0x0030). see Long Description for complete error code Nov 12 Fri 16:13:07 2270023 LxMxConsumer VrfTrace.cpp 80 Server Name: ADS1 VRF - Error bit(s) activated in Link Control Status Register (0x0030). The VRF is located at ICN1(ICN2), if ADS(ADS1) reports this error. VRF ID: 0x0 Link Control Status Register: 0x131000000000->
Applies to
- Models
- Discovery, Excite, Optima
- Product
- Discovery MR750. Also called DVMR. This product is compatible with 3.0T 20.0, 20.1_IB1, IB2, 21.0 and DV22.0 software only
- Software
- 20.1_IB1 and IB2 This release of software is applicable to Discovery MR450 and Discovery MR750 systems. See Long Description 20.1_IB1 is the unified Discovery MR450 and Discovery MR750 software release. Known internally to engineering as "DVIB". This release of software is applicable to Discovery MR450 and Discovery MR750 systems. 20.1_IB2 is the upgrade (bug fixes) for IB1.
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- TPS/MGD fails to download or reset. mgd_term windows fail to mount file system.
- The Carriage Fails to Advance to Latch to the Table and to Retract When it is Raised, Undocked or Lowered.
- Unable to Load Applications Software during restoreinfo Due to Corrupt saveinfo Disk.
- CWA ID100315. Auto and Manual Prescan Fails.
- Ghosted or Smeared Head Images Using Head Coil due to Head TR Assembly.
- A Copper Coolant Line or Pipe Internal to the MCS Cabinet Chiller Burst due to Water Remaining in Unit Freezing During Shipment.