GE Healthcare · MRSignaExciteDiscoveryOptima22405762223621200002352200002379
Application Software does not complete the boot process with TPS Download failure Due to Idle Overnight With Power On.
Symptom
Computer will not boot up to applications level, with the message on the screen that says Please do not interact with the system until this message disappears. Computer will not boot up to applications level, with the message on the screen that says -- > Please do not interact with the system until this message disappears. If the system does not come up in 15 minutes, please call your service representative.
Error message
2240576 Sending the security key request packet failed. Mon Mar 15 07:26:41 2004 Error: 2240576 Host: MMCLX_2 Process: sdm File: chkScrKey.c Line: 168 Sending the security key request packet failed. Make sure the applications needed to run the system are up and running properly. 2223621 Internal Software Error. Can't callback on undefined NMRID:hop_server. Mon Mar 15 07:26:41 2004 Error: 2223621 Host: MMCLX_2 Process: sdm File: mrmail_connect_mgr.c Line: 232 Internal Software Error. Can''t callback on undefined NMRID:hop_server. 200002352 A HOST_SHUTDOWN was initiated by the death of NSP. 200002379 Process RTPSIServer, pid 2114 exited with status=255 Mon Mar 15 07:26:41 2004 Error: 200002379 Host: MMCLX_2 Process: hostMonitor File: ssSigHandlers.c Line: 141 Process RTPSIServer, pid 2114 exited with status=255
Applies to
- Models
- Signa, Excite, Discovery, Optima
- Product
- Signa HDxT This product is for 1.5T Signa HDxT systems with 15.0 software and HDi systems with 15.0 software. This product is for 1.5T Signa HDxT systems with 15.0 software and HDi systems with 15.0 software.
- Software
- 15.0 For Product Signa HDxT and HDi only. -- NOT to be used with HDe. -- For Product Signa HDxT and HDi only. -- NOT to be used with HDe. --
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- Running grafidy3, and find there are spikes on the waveforms in the manual prescan display, both windows.
- TPS/MGD fails to download or reset. mgd_term windows fail to mount file system.
- Fails to Scan with TORSO Coil.
- The Carriage Fails to Advance to Latch to the Table and to Retract When it is Raised, Undocked or Lowered.
- AE title has changed on destination host.
- Unable to Load Applications Software during restoreinfo Due to Corrupt saveinfo Disk.