INX100, PRO, IQ+ Xray Stopped Restart Xray; If problem persists call Service is Displayed on the DL In room monitor
Symptom
INX100, PRO, IQ+ Xray Stopped Restart Xray; If problem persists call Service is Displayed on the DL In room monitor Xray Stopped Restart Xray; If problem persists call Service is Displayed on the DL In room monitor. Xray Stopped Restart Xray; If problem persists call Service is Displayed on the DL In room monitor
Error message
INX100: 1600010 Front: different frame nb between CF last notification and last image received on fiber link. X to X images may have been lost. 1600017 = Last DL Frame Id -not yet consolidated 1600010 Front: different frame nb between CF last notification and last image received on fiber link. 1 to 6 images may have been lost. Followed by Stop Sequence time out. 1600017 = Last DL Frame Id -not yet consolidated 1600010 Front: different frame nb between CF last notification and last image received on fiber link. X to X images may have been lost. where X = number of images lost. Typically followed by Stop Sequence time out: 1610034 IP software error 1610017 Front: Unable to get property as requested DO XRImProc control Frt_Component(s)_ETHERNET_Communication 0 0 user StopSequence NOT done due to: Last DL Frame Id -not yet consolidated Last DL Frame = DL FCIB, Last DL Image = RTAC FCIB 1610006 Front: Stop sequence timed out 810017 Front: user StopSequence NOT done due to: Disk Frame Vector -not yet consolidated DLGenericActorContext.cxx 2046 810006 Front: Stop sequence timed out 810004 "Front: Failed to stop sequence, 200205 Unexpected sequencing 2810052 An asynchronous error has been
Applies to
- Models
- Innova
- Product
- Innova X100 Monoplane Innova X100 Monoplane from product name Innova 2100, 3100 and 4100 Innova X100 Monoplane Innova 2100, 3100 and 4100
- Area
- X-ray Vascular
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray Vascular issues
- The Worklist does not refresh on the system when performing a query.
- Innova System boot failure
- INX1X; Message Limit switch engaged; LP4 Lateral Detector lift will not move after going to max SID using the Emergency Backout button on the lift cover because the lift hit maximum (Max) SID limit sw…
- Firewall is broadcasting DHCP addresses
- Cooling Failure; Shut System down and call Service is displayed on the Innova Image monitor
- No gantry motion is reported by the customer.