The Sumitomo compressor water flow or water temperature values are not within specifications.MAC00018 PDS Alarm Compress…
The Sumitomo compressor water flow or water temperature values are not within specifications.MAC00018 PDS Alarm Compressor water supply fault caused by water flow or temp being out of spec.Rebuild flo…
Symptom
MAC00018 PDS Alarm Compressor water supply fault caused by water flow or temp being out of spec. The OnWatch engine has determined that the water supply to the coldhead compressor from the chiller is out of specifications. The water flow or water temperature parameter is out of specifications. NOTE: The Digital Services (DS) Rules Engine detected this problem. This issue is only applicable when detected in this way, and should not be reused in Knowledge objects for normal reactive service. This is an automated alarm generated by the OnWatch program. An algorithm was run on the data uploaded from the MM3 into Insite2. The data shows that the water flow or water temperature values are out of specifications, The OnWatch engine algorithm used the engineering specifications supplied by the manufacture of the compressor, Sumitomo. This alarm needs to be resolved to extend the Coldhead and compressor lifespan.
Error message
MAC00018 PDS Alarm Compressor water supply fault caused by water flow or temp being out of spec The OnWatch engine has determined that the water supply to the coldhead compressor from the chiller is out of specifications. The water flow or water temperature parameter is out of specifications. NOTE: The Digital Services (DS) Rules Engine detected this problem. This issue is only applicable when detected in this way, and should not be reused in Knowledge objects for normal reactive service. This is an automated alarm generated by the OnWatch program. An algorithm was run on the data uploaded from the MM3 into Insite2. The data shows that the water flow or water temperature values are not with in specifications, The OnWatch engine algorithm used the engineering specifications supplied by the manufacturer of the compressor, Sumitomo. This alarm needs to be resolved to extend the Coldhead and compressor lifespan.
Applies to
- Product
- Magnet Monitor 3. Magnet Monitor 3 Magnet Monitor 3
- Software
- Magnet Monitor 3 Revision 1.56. Magnet Monitor 3 revision 1.56, distributed to sites with Connectivity automatically post FMI 60755 release on 6/23/2008. See Long Description for Fixes and Notes. Magnet Monitor 3 Revision 1.56 Software (formerly known as 1.55). Fixes New magnet type selection page with menus for both compressors. New remote commands to change the compressor selections. New uploaded properties to show the current compressor selections. A fix to the satellite interface so MM3 doesn't lose the sat link if it gets a malformed entitlement message. Changed configuration files so ABM and BOM magnets with DT500 sensors use the correct lookup tables. Disabled alarms actually won't generate alarms. The net mask no longer has to be entered with extra zeros (i.e. - 255.0.0.0 is now good enough instead of 255.000.000.000). The "Show Digital IO" web page shows all compressor types correctly - no more messages saying that Leybolds are inverted. New alarm limits for ABM and BOM for 2nd_stage_shield (is now 10K to 25K, was previously 3.5K to 10K). Changed Master Interval to 720 minutes for LCC and Non-Zero boil off magnets and 360 minutes for HFOs to reduce dispatch volume. NOTES •Software will be downloaded to all communicating sites except satellite modems. •Currently there is no CD that is orderable as a FRU for sites that do not have communication or have a satellite modem so that the software can be manually updated.
- Component
- 5113506 Water Flow Meter Rebuild Kit. SMILe 05/12/2005 "Spare Parts Announcement for Turbine Style Water Flow Meter". See Attachment and Long Description. SMILe 05/12/2005 "Spare Parts Announcement for Turbine Style Water Flow Meter". See Attachment and Long Description. This information is Property of GE - For GE Service Personnel Only Disclosure to Third Parties Prohibited Subject: Spare Parts Announcement for Turbine Style Water Flow Meter Effectivity: All Magnet Monitor systems using the turbine style water flow meter part number 2333825. Announcement : Part number 5113506, Water Flow Meter Rebuild kit, is now available and orderable through GPO stock. The Illustration below shows the hardware contents of the kit. NOTE: The Illustration did not successfully transfer to the Long Description. See the Attachment for the FULL SMILe and use the following Link to view Service Note 67097 . IMPORTANT! Make sure the water flow meter is installed in the correct orientation. Details on performance issues relating to mounting orientation and instructions on how to replace the internal components are detailed in Service Note 67097. A copy of the Service Note is attached for your convenience. Paul Senski LSI - MR Service Engineering (262) 521-60 52 GE Medical Systems SMILe's and Service Notes are copyright (c) to General Electric Company Inc with all rights reserved. SMILe's and Service Notes issued by GE Medical Systems are proprietary to GE Medical Systems. Disclosure to persons not employed by GE Medical Systems or not in possession of a Advanced Service Agreement with GE Medical Systems is prohibited.
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- Running grafidy3, and find there are spikes on the waveforms in the manual prescan display, both windows.
- OrthoMRI Network cable is unplugged
- TPS/MGD fails to download or reset. mgd_term windows fail to mount file system.
- CWA ID100060 Unable To Film.
- Fails to Scan with TORSO Coil.
- The Carriage Fails to Advance to Latch to the Table and to Retract When it is Raised, Undocked or Lowered.