Pular para o conteúdo principal
GE Healthcare · CTOptimaVCTBrightSpeed260107251

"Scan hardware Stopped Scan" with Axial Errors.

Symptom

"Scan hardware Stopped Scan" with Axial Errors. "Scan hardware Stopped Scan" with Axial Errors

Error message

Error: 260107251 Axial Motor Control (AMC) logic lost communication with the Axial Drive. See Long Discription for Details Error: 260107251 Axial Motor Control (AMC) logic lost communication with the Axial Drive. Mon Jul 19 07:41:43 2010 Error: 260107251 Host: tgp Process: tgp_subsys File: ds301.c Line: 828 Mon Jul 19 07:41:41 2010 Host : Table Gantry Processor Ermes # : 260107251 Exception Class : Secondary Severity : Sec/Soft File : ds301.c Line# : 828 Function : AXIAL CONTROL : Axial Communications Scan Type : None/Unknown Scan: 0/0/0 . Axial Motor Control (AMC) logic lost communication with the AXIAL drive (Comm Watchdog Failure)

Applies to

Models
Optima, VCT, BrightSpeed
Product
Optima CT660 10HW02.10.H40_P2_HS64_G_GMV 10HW33.8 H40_P2_HS64_G_GMV Optima CT660 Optima CT660 is a new design 64 slice scanner based on VCT and BrightSpeed technology. This is the first CT scanner as new Optima brand. check_config Product: Optima CT660 sw_version: 10HW02.10 or 10HW33.8 sw_hw_string: 10HW02.10.H40_P2_HS64_G_GMV or 10HW33.8_SP3-0-1.H40_P2_HS64_G_GMV host_id: 1943170864 tube_type: 19 gantry_type: GANTRY_HP_40 No. of processors: 8 Processor speed: 2527 memory: 24576 hinv CPU: GenuineIntel Intel(R) Xeon(R) CPU E5540 @ 2.53GHz 8 2527 MHz x86_64 Processors Secondary cache: 8192 KB FPU: GenuineIntel Intel(R) Xeon(R) CPU E5540 @ 2.53GHz Floating Point Main memory size: 24576 Mbytes SCSI controller 10: Version usb-storage Disk drive: unit 00 on SCSI controller 10, Lun 00 SCSI controller 9: Version usb-storage Disk drive: unit 00 on SCSI controller 9, Lun 00 SCSI controller 0: Version mptsas Disk drive: unit 00 on SCSI controller 0, Lun 00 Disk drive: unit 01 on SCSI controller 0, Lun 00 16550A UART serial port: 000003F8 Graphics board: VGA Ethernet interface configured: eth3 Ethernet interface configured: eth0 Ethernet interface configured: eth1 Dual Channel Display Table weight limit: GT1700V Table The Lite table ( currently for Japan Market) 450 Pounds (205 kg) Table: The normal table is 500 Pounds (227 kg) Table: X-Ray Tube Modified Performix D3187T Green Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare CT issues