PURE Calibration Scan Invalid Due TPS error at time of Cal Scan.
Symptom
PURE Calibration Scan Invalid Not Recognized But It Was Run See Long Description PURE Cal scan was run, then Sag T2 set up with PURE to run on the same coil config, but when the SCAN button is clicked to run the sag T2, an error message pops up at the bottom of the screen "PURE requires same cal position and landmark" yet there has been no landmark alteration, coil configs are the same for Cal and T2 series, scanner won't scan. Error message indicated that a valid PURE scan did not exist even though it appears that the calibration scan taken was valid. See below for error message logged: -------------------------------------------------- 2228004 ASMR02 NSP MH_MBOX_VRE:ed_ready_process 0 Exception Class: Unknown Severity: Unknown Function: Recon: PSD: Spin Echo Coil: 8Ch Body Upper Scan: 31214/3 No valid PURE calibration was found. A PURE scan must have the same coil, position, entry, and landmark as the most recent PURE calibration. --------------------------------------------------- SPRs MRIhc19850 & MRIhc21462.
Error message
2218527 Scanning has stopped. No Pure calibration was found Thu May 27 07:57:16 2010 Error: 2218527 Host: LX01 Process: scn File: MsaScanOpsScrn.m Line: 917 Scanning has stopped. No Pure calibration was found 2228004 No valid PURE calibration was found. A PURE scan must have the same coil, position, entry, and landmark as the most recent PURE calibration. 2228004 ASMR02 NSP MH_MBOX_VRE:ed_ready_process 0 Exception Class: Unknown Severity: Unknown Function: Recon: PSD: Spin Echo Coil: 8Ch Body Upper Scan: 31214/3 No valid PURE calibration was found. A PURE scan must have the same coil, position, entry, and landmark as the most recent PURE calibration. 2228004 ASMR02 NSP MH_MBOX_VRE:ed_ready_process 0 MException Class: Unknown Severity: Unknown Function: Recon: PSD: Spin Echo Coil: 8Ch Body Upper Scan: 31214/3 No valid PURE calibration was found. A PURE scan must have the same coil, position, entry, and landmark as the most recent PURE calibration.
Applies to
- Models
- Excite
- Product
- Excite HDx Includes "Excite HDi" system. 14.0 Software only.
- Software
- 14.0 M5 Excite HDx HDi Platforms only.
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- TPS/MGD fails to download or reset. mgd_term windows fail to mount file system.
- The Carriage Fails to Advance to Latch to the Table and to Retract When it is Raised, Undocked or Lowered.
- Unable to Load Applications Software during restoreinfo Due to Corrupt saveinfo Disk.
- CWA ID100315. Auto and Manual Prescan Fails.
- Ghosted or Smeared Head Images Using Head Coil due to Head TR Assembly.
- A Copper Coolant Line or Pipe Internal to the MCS Cabinet Chiller Burst due to Water Remaining in Unit Freezing During Shipment.