PURE Calibration Scan Invalid Due TPS error at time of Cal Scan.

Symptom

PURE Calibration Scan Invalid Not Recognized But It Was Run See Long Description PURE Cal scan was run, then Sag T2 set up with PURE to run on the same coil config, but when the SCAN button is clicked to run the sag T2, an error message pops up at the bottom of the screen "PURE requires same cal position and landmark" yet there has been no landmark alteration, coil configs are the same for Cal and T2 series, scanner won't scan. Error message indicated that a valid PURE scan did not exist even though it appears that the calibration scan taken was valid. See below for error message logged: -------------------------------------------------- 2228004 ASMR02 NSP MH_MBOX_VRE:ed_ready_process 0 Exception Class: Unknown Severity: Unknown Function: Recon: PSD: Spin Echo Coil: 8Ch Body Upper Scan: 31214/3 No valid PURE calibration was found. A PURE scan must have the same coil, position, entry, and landmark as the most recent PURE calibration. --------------------------------------------------- SPRs MRIhc19850 & MRIhc21462.

Error message

2218527 Scanning has stopped. No Pure calibration was found Thu May 27 07:57:16 2010 Error: 2218527 Host: LX01 Process: scn File: MsaScanOpsScrn.m Line: 917 Scanning has stopped. No Pure calibration was found

2228004 No valid PURE calibration was found. A PURE scan must have the same coil, position, entry, and landmark as the most recent PURE calibration. 2228004 ASMR02 NSP MH_MBOX_VRE:ed_ready_process 0 Exception Class: Unknown Severity: Unknown Function: Recon: PSD: Spin Echo Coil: 8Ch Body Upper Scan: 31214/3 No valid PURE calibration was found. A PURE scan must have the same coil, position, entry, and landmark as the most recent PURE calibration. 2228004 ASMR02 NSP MH_MBOX_VRE:ed_ready_process 0 MException Class: Unknown Severity: Unknown Function: Recon: PSD: Spin Echo Coil: 8Ch Body Upper Scan: 31214/3 No valid PURE calibration was found. A PURE scan must have the same coil, position, entry, and landmark as the most recent PURE calibration.

Applies to

Models
Excite
Product
Excite HDx Includes "Excite HDi" system. 14.0 Software only.
Software
14.0 M5 Excite HDx HDi Platforms only.
Area
MR

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare MR issues