GE Healthcare · MRExciteDiscovery126471120572230
Images Are Not Listed In The Browser but are Displayed in Autoview On A Linux HP Computer System scanning ok b…
Corrupt Image Database.
Symptom
Images Are Not Listed In The Browser but are Displayed in Autoview On A Linux HP Computer System scanning ok but images are not showing up in the browser list, can see them in the Autoview. Logout and bringing applications back up did not fix the problem.
Error message
9050 Too Many Users Thu May 10 00:46:59 2007 Error: 9050 Host: FIAJ3T Process: dcserver File: listener.c Line: 590 Too many users connected 9003 Registration failed (server DBWserver, host lx-mr) See Long Description Thu Apr 9 23:11:17 2009 Error: 9003 Host: lx-mr Process: netserver File: application.c Line: 305 Registration failed (server DBWserver, host lx-mr) Error: 9019 Version of the message is not compatible See Long Description Error: 9019 Host: STMROP Process: dbwserver File: application.c Line: 141 Version of the message is not compatible (version of message: STMROP:ppsServer.9391 - expected version: 2.5.1 - service name: NETserver - address: 6 - protocol: 0 - type: 1) 9071 Get Mail Failed in process_mail Thu Apr 29 10:02:11 2004 Error: 9071 Host: mrexcite Process: dbwserver File: proc.c Line: 385 get mail failed in process_mail() 9056 Connection to Netserver Failed, Exiting Thu Apr 29 10:02:11 2004 Error: 9056 Host: mrexcite Process: dbwserver File: server.c Line: 52 connection to Netserver failed, exiting... 3005 Can't connect with mrlx:DBWserver. Tue Jul 5 09:03:33 2005 Error: 3005 Host: mrlx Process: netserver File: netproc.c Line: 536 Can't connect with mrlx:DBWs
Applies to
- Models
- Excite, Discovery
- Product
- Excite Includes Excite 1 and Excite 2, 10.0, 11.0 and 11.1 Software.
- Software
- 11.1 For product 1.5T Excite only. Note, 3T Excite goes with software G3, not 11.0 or 11.1.
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- TPS/MGD fails to download or reset. mgd_term windows fail to mount file system.
- The Carriage Fails to Advance to Latch to the Table and to Retract When it is Raised, Undocked or Lowered.
- Unable to Load Applications Software during restoreinfo Due to Corrupt saveinfo Disk.
- CWA ID100315. Auto and Manual Prescan Fails.
- Ghosted or Smeared Head Images Using Head Coil due to Head TR Assembly.
- A Copper Coolant Line or Pipe Internal to the MCS Cabinet Chiller Burst due to Water Remaining in Unit Freezing During Shipment.