Unable to Boot Applications Software with Host Monitor Faults Due to Corrupt Image Database.
Symptom
Unable to boot Applications software due to a Host monitor Timeout after 250 seconds See Long Description This was a running system. The tech decided to reboot the system, and then it would never come all the way back up again. Applications software would not come up. After a while, the message "Host monitor Timeout after 250 seconds" was displayed. By viewing the message log from a C-shell using the commands shown below, we found the errors shown below. These same two errors were logged on every failed applications software boot attempt. The two messages are reporting the process "ifcc". Knowing that "ifcc" stands for "Image File Creation and Control", we suspected that the image database was corrupt and would need recovery. We suspected the system was unable to mount the image database completely, and this could be the reason that Applications software would not boot. Looking at the disk partitions using the command "df -k", the /export/home1 image partition was seen to be present (it was 56% full) but perhaps it was corrupt. cd /usr/g/service/log [enter] more gesys* [enter] Fri Sep 1 11:31:19 2006 200002372 signa3 hostMonitor ssProcStart.c 927 The process ifcc took too long to start up. Fri Sep 1 11:32:04 2006 200002352 signa3 hostMonitor ssProcStop.c 812 A HOST_SHUTDOWN was initiated by the death of ifcc.
Error message
200002352 A HOST_SHUTDOWN was initiated by the death of ifcc 200002372 The process ifcc took too long to start up. Fri Jun 10 08:09:19 2005 Error: 200002372 Host: lx-mr Process: hostMonitor File: ssProcStart.c Line: 904 The process ifcc took too long to start up. Hostmonitor Timeout after 250 seconds This message appears on the desktop only, it doesn't get logged in the message log This message appears on the desktop only, it doesn't get logged in the message log.
Applies to
- Models
- Excite
- Product
- Excite Includes Excite 1 and Excite 2, 10.0, 11.0 and 11.1 Software.
- Software
- 11.1 For product 1.5T Excite only. Note, 3T Excite goes with software G3, not 11.0 or 11.1.
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- TPS/MGD fails to download or reset. mgd_term windows fail to mount file system.
- The Carriage Fails to Advance to Latch to the Table and to Retract When it is Raised, Undocked or Lowered.
- Unable to Load Applications Software during restoreinfo Due to Corrupt saveinfo Disk.
- CWA ID100315. Auto and Manual Prescan Fails.
- Ghosted or Smeared Head Images Using Head Coil due to Head TR Assembly.
- A Copper Coolant Line or Pipe Internal to the MCS Cabinet Chiller Burst due to Water Remaining in Unit Freezing During Shipment.