The Sumitomo compressor water flow or water temperature values are not within specifications.MAC00019 PDS Alarm.Site Chi…
The Sumitomo compressor water flow or water temperature values are not within specifications.MAC00019 PDS Alarm.Site Chiller needs maintenance.SHeM 2.3.7
Symptom
MAC00019 PDS Alarm Compressor water supply fault caused by water flow or temp being out of spec. The OnWatch engine has determined that the water supply to the coldhead compressor from the chiller is out of specifications. The water flow or water temperature parameter is out of specifications. NOTE: The Digital Services (DS) Rules Engine detected this problem. This issue is only applicable when detected in this way, and should not be reused in Knowledge objects for normal reactive service. This is an automated alarm generated by the OnWatch program. An algorithm was run on the data uploaded from the MM3 into Insite2. The data shows that the water flow or water temperature values are out of specifications, The OnWatch engine algorithm used the engineering specifications supplied by the manufacture of the compressor, Sumitomo. This alarm needs to be resolved to extend the Coldhead and compressor lifespan.
Error message
MAC00019 PDS Alarm Compressor water supply fault caused by water flow or temp being out of spec The OnWatch engine has determined that the water supply to the coldhead compressor from the chiller is out of specifications. The water flow or water temperature parameter is out of specifications. NOTE: The Digital Services (DS) Rules Engine detected this problem. This issue is only applicable when detected in this way, and should not be reused in Knowledge objects for normal reactive service.
Applies to
- Product
- Magnet Monitor SHeM Advantech. Part Number: 2219400 (OBSOLETE, changes up to a MM3, 2394952 as of July, 2006) Modem Cable: 2276568 MultiTech Modem: 2245794 Magnet Monitor Proprietary Software: 2252032-3 See the Long Description for the link to download the following 4 manuals; LCC Magnet Mon. Hardware Install: 2230681 LCC ProActive Software Install & T/S: 2236995 HFO Magnet Mon. Hardware Install: 2261116 HFO ProActive Software Install & T/S: 227721 Proprietary, For GE Healthcare personnel Only This information is Property of GE Healthcare - For GE Healthcare Service Personnel Only. Disclosure to Third Parties Prohibited. Click on this link to reach the Magnet Service Documentation CD-Rom on the MR Engineering Service Documentation website. Part Number : 2219400 ( OBSOLETE , changes up to a MM3, 2394952 as of July, 2006 ) Modem Cable : 2276568 MultiTech Modem : 2245794 Magnet Monitor Proprietary Software : 2252032-3 The following 4 manuals may be downloaded from the above Magnet CD-Rom link. LCC Magnet Mon. Hardware Install: Direction 2230681 LCC ProActive Software Install & T/S: Direction 2236995 HFO Magnet Mon. Hardware Install: Direction 2261116 HFO ProActive Software Install & T/S: Direction 2277211
- Software
- SHeM Proprietary Software 2.3.7. SHeM Proprietary Software 2.3.7 SHeM Proprietary Software 2.3.7.
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- Running grafidy3, and find there are spikes on the waveforms in the manual prescan display, both windows.
- OrthoMRI Network cable is unplugged
- TPS/MGD fails to download or reset. mgd_term windows fail to mount file system.
- CWA ID100060 Unable To Film.
- Fails to Scan with TORSO Coil.
- The Carriage Fails to Advance to Latch to the Table and to Retract When it is Raised, Undocked or Lowered.