GE Healthcare · MRExcite2223885
Application Software does not complete the boot process with TPS Download failure Due to VRE Configuration.
Symptom
Application Software does not complete the boot process with TPS Download failure
Error message
2223885 System startup failed due to failure to communicate with the VRE!-> See Long Description 2223885 Host: hde-mr Process: logermes File: vreBmcUpCheck.pl Line: 251 Exception Class: Shutdown Function: Host: NSP System startup failed due to failure to communicate with the VRE!-> Extended Error: The system startup failure is caused by the failure to communicate with all configured ICNs. Please check that power is applied to all ICNs. Please check the Ethernet connections to all ICNs. You may also run all Ethernet and IPMI tests under VRE Communication Diagnostics to verify connectivity. As a last resort, VRE Configuration may be required to recover.
Applies to
- Models
- Excite
- Product
- Excite HDe. For Hino HDe 14.0 and HDe 15.0 Software Systems only
- Software
- HDe 15.0 For Hino Excite HDe 15.0 systems only.
- Component
- 5139480-2 8 PORT GIGABIT ETHERNET SWITCHING HUB See long description for important note FEMC Description: 8-Port Switch Kit with 4 cushions To view the most recent appropriate and detailed documentation, click to go to SERVICE METHODS. Note: BE CAREFUL when ordering this part. Per the FRU manuals, some products use this part for GOC and/or System Cabinet and some don't. Some products are supposed to use the 2272740-3 8 PORT 10/100 INTEL HUB SERVICE KIT as the FRU. Please check the FRU manual for your system to see whether this part should really be used on the Product and for the purpose (i.e. GOC and/or Sys Cab).
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- TPS/MGD fails to download or reset. mgd_term windows fail to mount file system.
- The Carriage Fails to Advance to Latch to the Table and to Retract When it is Raised, Undocked or Lowered.
- Unable to Load Applications Software during restoreinfo Due to Corrupt saveinfo Disk.
- CWA ID100315. Auto and Manual Prescan Fails.
- Ghosted or Smeared Head Images Using Head Coil due to Head TR Assembly.
- A Copper Coolant Line or Pipe Internal to the MCS Cabinet Chiller Burst due to Water Remaining in Unit Freezing During Shipment.