GE Healthcare · X-ray VascularInnova3800315
No Acquisition exposure, fluoro or record
Symptom
No Acquisition exposure, fluoro or record will not fluoro or record after boot. No issue with Positioner movement, DL, Rtac and detector is up. Innova 2100iq system will not fluoro or record after boot. No issue with Positioner movement, DL, Rtac and detector is up. Error 3200011
Error message
3800315 Text = Received bad value from IDC for sensor Fbck, debug Text = (null), recovery Class = DO, major Function /= XRTechOpt 3800315 Text = Received bad value from IDC for sensor Fbck, System impact: Possible image quality issue. Displayed message : None. You may see this in testing if you use lead or other thing to Fluoro. The system can not adjust dose correct from the last exposure to the new. because lookup conv table. Step to high for normal then step to low causing the image to change levels., You need aluminum block. Calibration issues If a issue check Digital Detector Calibration 3800315 Text = Received bad value from IDC for sensor Fbck, System impact: Possible image quality issue. Displayed message : None. You may see this in testing if you use lead or other thing to Fluoro. The system can not adjust dose correct from the last exposure to the new. because lookup conv table. Step to high for normal then step to low causing the image to change levels., You need aluminum block. Calibration issues If a issue check Digital Detector Calibration
Applies to
- Models
- Innova
- Product
- Innova 2000 Innova 2000 systems Innova 2000 systems
- Software
- $, Innova 2000 Service Pack FMI F4, HerSvcPack_2.02 HerSvcPack_2.02 DL Applications version 11.23.26 Ghost DL-1 "F" : 17.4 Ghost DL-1 "G" : 15.5 Ghost DL-2 : 16.4 Ghost DL-4 : NA DL : 11.23.26 DL Atlas Core : 3.1O-1 RTAC Atlas Core : 3.1O-2 IDC : 2.13 Calypso : 11.13_FMI_7 Calypso Uptime : 11.25_FMI Titan : H0.57 Pos. Motorola : 5.2Y3-2 Pos. Roadrunner : 5.0R
- Area
- X-ray Vascular
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray Vascular issues
- The Worklist does not refresh on the system when performing a query.
- Innova System boot failure
- INX1X; Message Limit switch engaged; LP4 Lateral Detector lift will not move after going to max SID using the Emergency Backout button on the lift cover because the lift hit maximum (Max) SID limit sw…
- Firewall is broadcasting DHCP addresses
- Cooling Failure; Shut System down and call Service is displayed on the Innova Image monitor
- No gantry motion is reported by the customer.