GE Healthcare · X-ray VascularInnova1050261
INX100, Lost All Gantry axis's drive or NO movements
Symptom
INX100, Lost All Gantry axis's drive or NO movements The Gantry axis's will not drive. The Innova Gantry is locked and will not drive the L-arm, Pivot, Arc, or Lift. Emergency backout works, L-arm clutch releases. Gantry Problem: reset the system to recover is displayed on the monitor The Gantry axis' will not drive. The Innova Gantry is locked and will not drive the L-arm, Pivot, Arc, or Lift. Emergency backout works, L-arm clutch releases. Gantry Problem: reset the system to recover is displayed on the monitor
Error message
INX100: 1050261 FRT PIVOT AXIS SWITCH ENGAGED (PRD BC) error code 1050261 FRT PIVOT AXIS SWITCH ENGAGED WR GantryAxis No Motion PIVOT_Limit_Switch 1 0 - Limit switch 2 problem (prd: BC) Z:/heroic/prd_task.c 638 MCB prd code BCH is displayed on the MCB is displayed in the error log. The Pivot MCB has a PRD code of BC displayed on it. INX100: 1050261 FRT PIVOT AXIS SWITCH ENGAGED (PRD BC) error code 1050261 FRT PIVOT AXIS SWITCH ENGAGED WR GantryAxis No Motion PIVOT_Limit_Switch 1 0 - Limit switch 2 problem (prd: BC) Z:/heroic/prd_task.c 638 MCB prd code BCH is displayed on the MCB is displayed in the error log. The Pivot MCB has a PRD code of BC displayed on it. 1050261: Front: FRT PIVOT AXIS SWITCH ENGAGED; Debug Text: - Extra course switch engaged or 24V failure (4AB6)
Applies to
- Models
- Innova
- Product
- Innova X100 Monoplane Innova X100 Monoplane from product name Innova 2100, 3100 and 4100 Innova X100 Monoplane Innova 2100, 3100 and 4100
- Software
- $ Unity M4 SP3.2 DL_Unity_4.18.9, FMI 12105 Unity M4 SP3.2 DL_Unity_4.18.9 FMI 12105 Unity M4 SP3.2 DL_Unity_4.18.9, FMI 12105 healthpage tag for this software is UNITY_M4_FMI_4.21 212009270 03/26/2010 13:31 GMT
- Area
- X-ray Vascular
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray Vascular issues
- The Worklist does not refresh on the system when performing a query.
- Innova System boot failure
- INX1X; Message Limit switch engaged; LP4 Lateral Detector lift will not move after going to max SID using the Emergency Backout button on the lift cover because the lift hit maximum (Max) SID limit sw…
- Firewall is broadcasting DHCP addresses
- Cooling Failure; Shut System down and call Service is displayed on the Innova Image monitor
- No gantry motion is reported by the customer.