GE Healthcare · CTBrightSpeedVCT260111021225673032636260111007
BrightSpeed HPower, Velocity or Delight HPower
Symptom
Gantry Control Pad Flashing ERR and will not move the table. Gantry Control Pad Flashing "err" and will not move the table
Error message
Error: 260111021 GUIF CAN node response timeout See LD for details Wed Apr 4 16:55:13 2007 Error: 260111021 Host: tgp Process: tgp_subsys File: guif_can_mgr2.c Line: 1453 Wed Apr 4 16:55:13 2007 Host : Table Gantry Processor Ermes # : 260111021 Exception Class : Secondary Severity : Pri/Soft File : guif_can_mgr2.c Line# : 1453 Function : OPERATOR INPUT/OUTPUT : Gantry UIF Communications Scan Type : None/Unknown Scan: 9106/1/0 GUIF CAN node response timeout. Node part number 2256730. Node serial number 32636. Node CAN ID# 1. Error: 260111007 Communication reestablished to GUIF CAN node ID# 1 (or nodes 2,3,4) See LD for details Wed Apr 4 16:55:13 2007 Error: 260111007 Host: tgp Process: tgp_subsys File: guif_can_mgr2.c Line: 1908 Wed Apr 4 16:55:13 2007 Host : Table Gantry Processor Ermes # : 260111007 Exception Class : Secondary Severity : Pri/Soft File : guif_can_mgr2.c Line# : 1908 Function : OPERATOR INPUT/OUTPUT : Gantry UIF Communications Scan Type : None/Unknown Scan: 9106/1/0 Communication reestablished to GUIF CAN node ID# 1. Node part number 2256730. Node serial number 32636.
Applies to
- Models
- BrightSpeed, VCT
- Product
- BrightSpeed HPower, Delight, Velocity or MERI HPower HP_P_G4_G_HPT Excel HP_P_G8_G_HPT Edge HP_P_G16_G_HPT Elite HP_P_G16_G_GMV Elite HP_P_P16_G_GMV Elite HP_P_M16_G_HPT BrightSpeed Method of remote software hardware identification check_config swhwinfo List of Supported Console Types : HP_P_G16_ G _HPT Note: G could be GRE, AIO or TIO - check with: cat /usr/g/config/INFO | grep CONSOLETYPE GOC4 AIO TIO List of softwares the product can run: 08BW20.1 07MW11.10 08BW44.1 ( Delight ) 09HW30.4 ( Velocity ) 09BW35.11 ( MERI - Pancake DAS ) FAQ's 1. All BrightSpeed Power Systems use the Performix tube D3186T HP_P_G4_G_HPT (Excel - H-Power Table) HP_P_G8_G_HPT (Edge -H-Power Table ) HP_P_G16_G_HPT (Elite -H-Power Table ) HP_P_G16_G_GMV (Elite -Global Table Mid Value - modified GT1700 no IMS ) Note: G could be GRE, AIO or TIO (check with: cat /usr/g/config/INFO | grep CONSOLETYPE ) BrightSpeed Elite Power Systems will only be sold as Velocity System starting in 2Q/2010. Delight Elite Power being phased out 1Q/2010 BrightSpeed Power 4 & 8 slice systems have been discontinued due to restructuring of the product lineup. Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required