INX1PRO-IQ, Sequence lost due to Worklist issues Harmony M3 release.
Symptom
INX1PRO-IQ+, Sequence lost due to Worklist issues Harmony M3 release. INX1PRO-IQ+, Sequence lost due to Worklist issues, Harmony M3 release.. See long description for further informations INX1PRO-IQ+: Sequence lost due to Worklist issues Several records sequence were lost due to a worklist issue on Harmony M3 release. Scenario for the issue is the following: Imported one worklist run few acquisitions Again imported another worklist entry for same patient Cancelled that import operation Created a manual patient with the ID resembling Run one record Warning messages. Last record lost
Error message
2800007, Harmony M3 release.01/201 Review of a sequence is unavailable, due to data inconsistency. 2800007, 2222,WR,DEFAULT" Review of a sequence is unavailable, due to data inconsistency",, XRSubSysMgrDL,Comparing Patient Name in DB and Ctxt. See long description to get full pattern Harmony M3 release.01/2010 Typical pattern of sequence lost due to worklist issue 2800007,"Review of a sequence is unavailable, due to data inconsistency",2222,WR,DEFAULT, XRSubSysMgrDL,Comparing Patient Name in DB and Ctxt 2800007,"Review of a sequence is unavailable, due to data inconsistency",2222,WR,DEFAULT, XRSubSysMgrDL, _thePipe.build() 2800007,"Review of a sequence is unavailable, due to data inconsistency",2222,WR,DEFAULT, XRSubSysMgrDL, Failed call to startViewer 2800034 DO XRSubSysMgrDL Read operation failed in database. Debug: Database error occured: can't read study record. 1610034, IP software error,2222,DO,DEFAULT, XRImProc,(null), Could not find file Cardiac_20091123_172305296F_75700000010_75700000011.txt 1610034, IP software error,2222,DO,DEFAULT, XRImProc,(null), Could not find file Cardiac_20091123_172449343F_75700000010_75700000011.txt 2800031, Data inconsistency failure,2222,WR,DEF
Applies to
- Models
- Innova
- Product
- Innova X100 Monoplane Innova X100 Monoplane from product name Innova 2100, 3100 and 4100 Innova X100 Monoplane Innova 2100, 3100 and 4100
- Software
- $ INX1PRO or IQ+,Harmony_M3 INX1PRO or IQ+, Harmony_M3 Product is called INX1PRO or IQ+: Harmony_M3 sw release applicable to Harmony systems.
- Area
- X-ray Vascular
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray Vascular issues
- The Worklist does not refresh on the system when performing a query.
- Innova System boot failure
- INX1X; Message Limit switch engaged; LP4 Lateral Detector lift will not move after going to max SID using the Emergency Backout button on the lift cover because the lift hit maximum (Max) SID limit sw…
- Firewall is broadcasting DHCP addresses
- Cooling Failure; Shut System down and call Service is displayed on the Innova Image monitor
- No gantry motion is reported by the customer.