INX100, Lost All Gantry axis's drive or NO movements

Symptom

INX100, Lost All Gantry axis's drive or NO movements The Gantry axis's will not drive. The Innova Gantry is locked and will not drive the L-arm, Pivot, Arc, or Lift. Emergency backout works, L-arm clutch releases. Gantry Problem: reset the system to recover is displayed on the monitor The Gantry axis' will not drive. The Innova Gantry is locked and will not drive the L-arm, Pivot, Arc, or Lift. Emergency backout works, L-arm clutch releases. Gantry Problem: reset the system to recover is displayed on the monitor

Error message

All MCB's with PRD code "BD" displayed during Positioner boot sequence All MCB's with PRD code "BD" displayed during Positioner boot sequence. See long description for pattern details in system errlog. In System errlog, following pattern will be found; 1050055 Lift AXIS POWER WR GantryAxis No Motion Lift_AXIS_POWER 0 0 - Power input from K3 problem (prd: BD) 1050016 Carc AXIS POWER WR GantryAxis No Motion Carc_AXIS_POWER 0 0 - Power input from K3 problem (prd: BD) 1050103 Pivot AXIS POWER WR GantryAxis No Motion Pivot_AXIS_POWER 0 0 - Power input from K3 problem (prd: BD) 1050042 Larm AXIS POWER WR GantryAxis No Motion Larm_AXIS_POWER 0 0 - Power input from K3 problem (prd: BD) Then those errors will be cleared after approximately 10 sec. 1050055 CLEAR WR GantryAxis No Motion Lift_AXIS_POWER 1050016 CLEAR WR GantryAxis No Motion Carc_AXIS_POWER 1050103 CLEAR WR GantryAxis No Motion Pivot_AXIS_POWER 1050042 CLEAR WR GantryAxis No Motion Larm_AXIS_POWER This full pattern will then be repeated endlessly as long as the problem is not solved . Note: We may also have the following errors (which are a consequence of the previous error): Positioner may detect that all axes are in "Limit sw

Applies to

Models
Innova
Product
X Innova 2100 Do not use Innova 2100iq System Innova 2100
Software
$ Unity M4 SP3.2 DL_Unity_4.18.9, FMI 12105 Unity M4 SP3.2 DL_Unity_4.18.9 FMI 12105 Unity M4 SP3.2 DL_Unity_4.18.9, FMI 12105 healthpage tag for this software is UNITY_M4_FMI_4.21 212009270 03/26/2010 13:31 GMT
Area
X-ray Vascular

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.