Unexpected RF Amplifier Errors Seen During UPM Functional Checks.
Symptom
Unexpected RF Amplifier Errors Seen During UPM Functional Checks See Long Description CSO 1-2441793235 The expected UPM trips occur during UPM Functional Checks, but some extra "RF Amplifier Error"s are also seen, so FE is unsure whether the checks passed or failed, see below for the expected errors, and below that the ones that we aren't sure about. These errors are normal and expected to occur during the UPM Functional Checks. In fact, they must occur for the checks to pass. Peak UPM Trip Error: 2254782 The Universal Power Monitor has detected Peak Power Exceeded on the Narrow Band Body Amplifier. Pulse Width Trip Error: 2254791 The Universal Power Monitor detected a Pulse Width fault on the Narrow Band Body Amplifier. Pulse Duty Cycle Trip Error: 2254792 The Universal Power Monitor detected a Duty Cycle fault on the Narrow Band Body Amplifier . ================================================================ But the errors shown below are also occurring during the UPM Functional Checks. Is this normal or does this indicate a failure of the UPM Functional Checks? Is there a problem with the system? Error: 2248763 RF Amplifier Error. RF amplifier failed to power off, in the allotted amount of time, when commanded to do so. Please power cycle the RF Subsystem and perform a TPS Reset. Error: 2248765 RF Amplifier Error. RF amplifier failed to go to operate when commanded to do so. Please power cycle the RF Subsystem and perform a TPS Reset. Error: 2248775 RF Amplifier Error. The RF amplifier failed to go into the commanded mode (head or body), or took too long to go to commanded mode. Please power cycle the RF Subsystem and perform a TPS Reset.
Error message
2248775 RF Amplifier Error. The RF amplifier failed to go into the commanded mode (head or body), or took too long to go to commanded mode. Please power cycle the RF Subsystem and perform a TPS Reset See Long Description Error: 2248775 RF Amplifier Error. The RF amplifier failed to go into the commanded mode (head or body), or took too long to go to commanded mode. Please power cycle the RF Subsystem and perform a TPS Reset. 2248765 RF Amplifier failed to go to operate when commanded to do so Error: 2248765Host: MR3T Process: NSPFile: SCP:../rf nb contro Line: 2102Exception Class: Unknown Severity: UnknownFunction: RF: RF TransmitPSD: Unknown Coil: Unknown Scan: -1/-1RF Amplifier Error. RF amplifier failed to go to operate when commanded to do so. Please power cycle the RF Subsystem and perform a TPS Reset. 2248763 RF Amplifier Error RF amplifier failed to power off in the allotted amount of time when commanded to do so 2248763 RF Amplifier Error. RF amplifier failed to power off, in the allotted amount of time, when commanded to do so. Please power cycle the RF Subsystem and perform a TPS Reset.
Applies to
- Models
- Excite
- Product
- Excite HDe. For Hino HDe 14.0 and HDe 15.0 Software Systems only
- Software
- HDe 15.0 For Hino Excite HDe 15.0 systems only.
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- TPS/MGD fails to download or reset. mgd_term windows fail to mount file system.
- The Carriage Fails to Advance to Latch to the Table and to Retract When it is Raised, Undocked or Lowered.
- Unable to Load Applications Software during restoreinfo Due to Corrupt saveinfo Disk.
- CWA ID100315. Auto and Manual Prescan Fails.
- Ghosted or Smeared Head Images Using Head Coil due to Head TR Assembly.
- A Copper Coolant Line or Pipe Internal to the MCS Cabinet Chiller Burst due to Water Remaining in Unit Freezing During Shipment.