Ingrid errors 3800331, 3602085, 3602087, May see a message, Warning.
Symptom
Ingrid errors 3800331, 3602085, 3602087, May see a message, Warning. Run time 21sec. May see message like; Acquisition in 4 sec. Release switch to abort. 3800331 The innova system reports bad actual techniques during an aquisition, 3602085 Max spit error KV regulation code 8. 3602087 7 kV reg on kV rise are all regulation related. These were non tube related spits and replacing the Ingrid fixed the problem. May see a message, Warning. Run time 21sec. Acquisition in 4 sec. Release switch to abort.
INX100, PRO, IQ+ Xray Stopped Restart Xray; If problem persists call Service is Displayed on the DL In room monitor Xray Stopped Restart Xray; If problem persists call Service is Displayed on the DL In room monitor. Xray Stopped Restart Xray; If problem persists call Service is Displayed on the DL In room monitor
Error message
3800331 or 3900331 for Lat. Bad actual techniques received in acquisition DO XRTechOpt EM Component(s)_Tube 1 1 (null) XRPAtlasLogger.cppXXX 3800331 or 3900331 for Lat.1 Bad actual techniques received in acquisition DO XRTechOpt EM Component(s)_Tube 1 1 (null) XRPAtlasLogger.cppXXX The Jedi has detected bad actual techniques during the acquisition, it will restart Xray. If the system issue continues, error 3800331 will be logged 6 times and xray aborted on the 7th fault. If X-ray is aborted review the error code imediately after the 6 3800331 errors logged in the log for the root cause of the exposure abort.
Applies to
- Models
- Innova
- Product
- Innova X100 Monoplane Innova X100 Monoplane from product name Innova 2100, 3100 and 4100 Innova X100 Monoplane Innova 2100, 3100 and 4100 Innova X1 X1 Biplane Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System
- Area
- X-ray Vascular
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray Vascular issues
- The Worklist does not refresh on the system when performing a query.
- Innova System boot failure
- INX1X; Message Limit switch engaged; LP4 Lateral Detector lift will not move after going to max SID using the Emergency Backout button on the lift cover because the lift hit maximum (Max) SID limit sw…
- Firewall is broadcasting DHCP addresses
- Cooling Failure; Shut System down and call Service is displayed on the Innova Image monitor
- No gantry motion is reported by the customer.