GE Healthcare · X-ray VascularInnova120011413001141200111130111
154744 Xray not Available - Reset System; If Problem Persists Call Service is displayed on the Image Monitor.
Symptom
Xray not Available - Reset System; If Problem Persists Call Service is displayed on the Image Monitor. Xray not Available - Reset System; If Problem Persists Call Service is displayed on the Monitor.
Error message
error Code = 1200114, or (1300114 BiPlane) error Text = ERR_DETECTOR_BOOT_WARNING followed by error Code = 1200111,(130111 for BIPLANE) error Text = ERR_DETECTOR_BOOT_FAILURE System impact: Boot failure. Displayed message : "Xray aborted - Restart Xray; if problem persists, call Service". error Code = 1200114 or (1300114 BiPlane), error Text = ERR_DETECTOR_BOOT_WARNING , debug Text += Detector com error: CDetectorDipb::waitRxCommandDm RX read timeout (, recovery Class = DO, major Function /= XRImDet followed by error Code = 1200111, error Text = ERR_DETECTOR_BOOT_FAILURE, debug Text /= , recovery Class = IH, major Function /= XRImDet System impact: Boot failure. Displayed message : "Xray aborted - Restart Xray; if problem persists, call Service". error Code = 1200114 or (1300114 BiPlane), error Text = ERR_DETECTOR_BOOT_WARNING , debug Text += Detector com error: CDetectorDipb::waitRxCommandDm RX read timeout (, recovery Class = DO, major Function /= XRImDet followed by error Code = 1200111, error Text = ERR_DETECTOR_BOOT_FAILURE, debug Text /= , recovery Class = IH, major Function /= XRImDet debug text statement := Detector com error: CDetectorDipb::waitRxCommandDm RX read timeout
Applies to
- Models
- Innova
- Product
- Innova X1 X1 Biplane Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System
- Software
- $ M4 SPAD BIP_4.18.5, DL_SPAD_4.15.1 FMI 12108 $New, M4 SPAD BIP_4.18.5, DL_SPAD_4.15.1 FMI 12108 or $ new, Innova Biplane M4 BIP_4.18.5, DL_4.15.1 FMI 12108 $New, M4 SPAD BIP_4.18.5, DL_SPAD_4.15.1 FMI 12108 or $ new, Innova Biplane M4 BIP_4.18.5, DL_4.15.1 FMI 12108
- Area
- X-ray Vascular
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray Vascular issues
- The Worklist does not refresh on the system when performing a query.
- Innova System boot failure
- INX1X; Message Limit switch engaged; LP4 Lateral Detector lift will not move after going to max SID using the Emergency Backout button on the lift cover because the lift hit maximum (Max) SID limit sw…
- Firewall is broadcasting DHCP addresses
- Cooling Failure; Shut System down and call Service is displayed on the Innova Image monitor
- No gantry motion is reported by the customer.