GE Healthcare · MRExcite2253518164362228016222466622535172228010
Array Processor Errors Due to Master AP Board.
Symptom
Auto Prescan Failure
Error message
2253518 The system did not find the right number of CPUs on the AP boards. Only 6 CPUs were found when there should be 8. This indicates that one of the AP boards may be partially defective.-> See Long Description 2253518 2 WFBIMRI diagCoord apBld.c 324 Diagnostic: Dual Board AP Mem Iteration: 1 of 1 Action: 1 Task ID: 0x3fa6948 Time: 16436 Object: APS Test Task The system did not find the right number of CPUs on the AP boards. Only 6 CPUs were found when there should be 8. This indicates that one of the AP boards may be partially defective.-> Extended Error : There should be 4 CPUs on each AP board. If there are two AP boards, this test can't tell which board is defective. Try reseating boards and verify each is in correct slot. If problem persists then replace single AP Board. If dual AP then configure to single AP and run diag again to isolate failure. 2228016 Internal AP software error See Long Description Please consult file /usr/g/service/log/aperror.log for more information. 2224666 Auto Prescan failed, Autoshim failed in Fermi filter creation. Fri Feb 26 19:33:12 1999 Error: 2224666 Host: lx-mr Process: psc File: PscMainControl.m Line: 919 Auto Prescan failed, Autoshim fa
Applies to
- Models
- Excite
- Product
- Excite Includes Excite 1 and Excite 2, 10.0, 11.0 and 11.1 Software.
- Software
- 11.1 For product 1.5T Excite only. Note, 3T Excite goes with software G3, not 11.0 or 11.1.
- Component
- SecondOpinion MERCURY 910-07072 MINERVA II MASTER 2325947-12 See comments in resolution concept for second opinion requirements before ordering this part
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- TPS/MGD fails to download or reset. mgd_term windows fail to mount file system.
- The Carriage Fails to Advance to Latch to the Table and to Retract When it is Raised, Undocked or Lowered.
- Unable to Load Applications Software during restoreinfo Due to Corrupt saveinfo Disk.
- CWA ID100315. Auto and Manual Prescan Fails.
- Ghosted or Smeared Head Images Using Head Coil due to Head TR Assembly.
- A Copper Coolant Line or Pipe Internal to the MCS Cabinet Chiller Burst due to Water Remaining in Unit Freezing During Shipment.