GE Healthcare · MRExcite224941023639224941222494322249411
Intermittent MGD - PCI, Raven, Serr, PERR, Harrier errors that stop scanning or TPS reset failing.
Symptom
Intermittent MGD - PCI, Raven, Serr, PERR, Harrier errors that stop scanning or TPS reset failing. How to troubleshoot? see long One or more of these errors occur intermittently. How do we go about troubleshooting this type of problem? 2249410 A PCI error occured. The PCI Parity Error PERR was asserted. 2249411 A PCI error was detected, but message queue send failed 2249412 A PCI error occured. The PCI Parity Error PERR was asserted. 2249432 A PCI error occured. The PCI System Error SERR was asserted.
Error message
2249410 A PCI error occured. The PCI Parity Error PERR was asserted. Error: 2249410 File: excLog.c Line: 1132 Task ID: 0x3ac1d68 Time: 23639 Object: AGP A PCI error occured. The PCI Parity Error PERR was asserted. Raven Err Enable Reg: 0x3F; Raven Err Status Reg: 0x88 Raven Err Address Reg: 0x0; Raven Err Attribute Reg: 0x0. Additional information in /usr/g/service/log/vxPciLg-5c2c 2249412 A PCI error occured. The PCI Parity Error PERR was asserted. 2249412 MRS1_OC0 diagCoord excLog.c 1357 Task ID: 0x3dcdef0 Time: 6163 Object: SCP A PCI error occured. The PCI Parity Error PERR was asserted. Qspan PCI Status Reg: 0x8390; Qspan Interrupt Status Reg: 0x30408C00 Qspan Interrupt Control Reg: 0x30600000. Additional information in /usr/g/service/log/vxPciLg-16d9 2249432 A PCI error occurred. The PCI System Error SERR was asserted Jun 17 Tue 11:02:15 2249432 diagCoord excLog.c 1338 Task ID: 0x6eca730 Time: 7430 Object: AGP Exception Class: Unknown Function: Software/Firmware/Config: N/A A PCI error occurred. The PCI System Error SERR was asserted. Harrier Err Enable Reg: 0xFFF0E000; Harrier Err Status Reg: 0x04000000. Harrier Err Address Reg: 0x00000000; Harrier Err Attribute Reg: 0x0000
Applies to
- Models
- Excite
- Product
- Excite HD For 12.0 1.5T Systems only.
- Software
- 12.0 Excite HD and 3T Excite HD products only
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- TPS/MGD fails to download or reset. mgd_term windows fail to mount file system.
- The Carriage Fails to Advance to Latch to the Table and to Retract When it is Raised, Undocked or Lowered.
- Unable to Load Applications Software during restoreinfo Due to Corrupt saveinfo Disk.
- CWA ID100315. Auto and Manual Prescan Fails.
- Ghosted or Smeared Head Images Using Head Coil due to Head TR Assembly.
- A Copper Coolant Line or Pipe Internal to the MCS Cabinet Chiller Burst due to Water Remaining in Unit Freezing During Shipment.