3 D spin fails to complete its test spin

Symptom

3 D spin fails to complete its test spin 3-d test does not complete its test spin. check the movements of the gantry per this instruction After the spin test completes, you have to stay on the test button until it goes all the way back to the start position at Patient right side to settle the gantry to start the high speed spin. Another possibility could be that you may be getting some counts from another position of the gantry or the table, everything has to stay absolutely still during the spin. Check that your L belt isn't loose and the table isn't moving, things like that. Could put scope on encoder and pot test points for each axis that should be stationary to see if it is getting any encoder pulses or changes in pot voltage. Another possibiliy is any gantry positioon not reaching the anticipated positon in software. Example the SID is set at 120CM, if it varies more than a half a CM from this there will be an errro created in the Spin3DCalib.log on the AWW. etc. Checking the positoner CPU trace is another good toubleshooting tip. Here is an Example of a VME-344GE trace: Result of “mini-reset” that occurs during a 3D spin test…Result of “mini-reset” that occurs during a 3D spin test… Push and hold the “test” button on the TSSC... Gantry moves to: L-arm = 3 degrees C-arc (Caudal) = 6 degrees Pivot (LAO) = 99 degrees II SID = 125 cm TV camera = 3 degree rotation Positioner CPU board “resets” All encoder history is cleared out with this “reset”. ( the following is seen on laptop with the Terminal window viewing the SMM162P - 344GE CPU board with the #2143282 RS-232 serial cable connected to Serial Port 1 / Console ) Handling PRDs ... PRD comm test. Frame received from board #09 SIB PRD comm test. Frame received from board #00 L-arm Smart-Amp PRD comm test. Frame received from board #01 C-Pivot Smart-Amp PRD comm test. Frame received from board #02 C-arm Smart-Amp PRD comm test. Frame received from board #03 II-Lift Smart-Amp PRD Result board #00 : 0x0001 PRD Result board #01 : 0x0001 PRD Result board #02 : 0x0001 PRD Result board #03 : 0x0001 PRD Result board #09 : 0x0001 PRD global status: 0x0001 Send error code:0x9500, HW=0x00cc, User=0x0000 Initializing SmartAmps... Gantry moves to: II SID = 120 cm L-arm = 0 degrees C-arc (Caudal) = 0 degrees Pivot (RAO) = 111 degrees TV Camera = 0 degrees Pivot (RAO) drives to: 108 degrees System ready for 3D spin… (release the test button on the TSSC) During the actual acquisition 3D spin, the Pivot drives from 108 degrees RAO to 96 degrees LAO during the Mask acquisition phase, then moves back to 108 degrees RAO, and then drives to 96 degrees LAO for the Subtraction acquisition phase.

Error message

1400300 Frontal: DIPB power up tests failure, followed by 1400001, 1400002, 1400019, 1800019 1400300 Frontal: DIPB power up tests failure; IH, [FPGA_Driver::DIPB_init] failed to initialize DIPB 1400001 Front: Software error IH; [SystemInterfaceBoardDriver::readHwConfigParameters] BOARD_TYPE (NONE) unknown 1400002 Front: Operationg system error IH; [ImageAcquisitionMonitoring::ImageAcquisitionMonitoring] Unable to get instance of Gitane Driver 1400019 Front: Software error DO; [Preprocessi 1400300 Frontal: DIPB power up tests failure, followed by 1400001, 1400002, 1400019, 1800019 1400300 Frontal: DIPB power up tests failure; IH, [FPGA_Driver::DIPB_init] failed to initialize DIPB 1400001 Front: Software error IH; [SystemInterfaceBoardDriver::readHwConfigParameters] BOARD_TYPE (NONE) unknown 1400002 Front: Operationg system error IH; [ImageAcquisitionMonitoring::ImageAcquisitionMonitoring] Unable to get instance of Gitane Driver 1400019 Front: Software error DO; [PreprocessingDriver::getInstance] IP_BOARD_TYPE(NONE) is not recognized 1800019 Front: Software error DO; [DigAbdDriver::getInstance] IP_BOARD_TYPE(NONE) is not recognized; assuming DIPB by default

Applies to

Models
Innova
Product
Innova X1 X1 Biplane Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System
Area
X-ray Vascular

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.