Gantry motion is reduced to half speed
Symptom
Gantry motion is reduced to half speed Gantry motion is reduced to half speed. The problem does not disappear when disabling the anti collision software in the PST. Moreover, there is no level 1 / Level 1 bis collision detected through PST (as a collision level 1 / 1 bis may reduce gantry speed). For a system without capacitive sensors option installed, maximum speed allowed (outside collision zone) is 15 °/sec. When looking at speed command in the PST, maximum value is 75 (ie 7.5 °/sec) instead of 150 (corresponding to normal case 15 °/sec wo capacitive sensors). For a system with capacitive sensors option installed, maximum speed allowed (outside collision zone) is 20°/sec. When looking at speed command in the PST, maximum value is 100 (ie 10 °/sec) instead of 200 (corresponding to normal case 20 °/sec w capacitive sensors).
Error message
1050272 PIB 230V monitoring - Warning. Seen in the error log and not cleared after 10 sec. Exact error reported in the error log is: POS 1050272 PIB 230V MONITORING WR PositionerPower Speed Degraded Frt_Component(s)_Positioner_Martek 1050272 PIB 230V monitoring - Warning. Seen in the error log and not cleared after 10 sec. Exact error reported in the error log is: POS 1050272 PIB 230V MONITORING WR PositionerPower Speed Degraded Frt_Component(s)_Positioner_Martek
Applies to
- Models
- Innova
- Product
- Innova X100 Monoplane Innova X100 Monoplane from product name Innova 2100, 3100 and 4100 Innova X100 Monoplane Innova 2100, 3100 and 4100 Innova X1 X1 Biplane Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System
- Component
- Positioner Gantry Positioner Gantry Positioner Gantry 230 Volt Martek 5152133 230 volt Martek Part number 5152133 part #:5152133 AC-AC 230VAC 1.5KW CONVERTER MARTEK Replace 230 volt Martek Part number 5152133 part #:5152133 AC-AC 230VAC 1.5KW CONVERTER MARTEK
- Area
- X-ray Vascular
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray Vascular issues
- The Worklist does not refresh on the system when performing a query.
- Innova System boot failure
- INX1X; Message Limit switch engaged; LP4 Lateral Detector lift will not move after going to max SID using the Emergency Backout button on the lift cover because the lift hit maximum (Max) SID limit sw…
- Firewall is broadcasting DHCP addresses
- Cooling Failure; Shut System down and call Service is displayed on the Innova Image monitor
- No gantry motion is reported by the customer.