GE Healthcare · MRExcite224485822445932244594224485522445852244586
SGA Power Supply Internal Wiring Fault or Control Undervoltage Due to SGA Power Supply.
Symptom
Will Not Scan with Gradient Errors.
Error message
2244858 The GP is reporting SGA Power Supply Internal Wiring Fault or Control Undervoltage. the same error as 2244593 on 11X, G3 and 2244594 on 12X, E2, 14M4 (HDx, HDe), and openMR4,5. 2244858 error code on Post 14M5 is the same error as 2244593 on 11X, G3 and 2244594 on 12X, E2, 14M4 (HDx, HDe), and openMR4,5. 2244858 The GP is reporting SGA Power Supply Internal Wiring Fault or Control Undervoltage. 2244855 The SGA Power Supply failed to go to Ready when commanded, or came out of Ready. Same as 2244585 and 2244586. 2244855 errorcode on Post 14M5 is the same error as 2244585 on 11X, G3 and 2244586 on 12X, E2, 14M4 (HDx, HDe). 2244855 The SGA Power Supply failed to go to Ready when commanded, or came out of Ready. 2244855 errorcode on Post 14M5 is the same error as 2244585 on 11X, G3 and 2244586 on 12X, E2, 14M4 (HDx, HDe).2244855 The SGA Power Supply failed to go to Ready when commanded, or came out of Ready.
Applies to
- Models
- Excite
- Product
- Excite Includes Excite 1 and Excite 2, 10.0, 11.0 and 11.1 Software.
- Software
- 11.1 For product 1.5T Excite only. Note, 3T Excite goes with software G3, not 11.0 or 11.1.
- Component
- 2334862-2 ACGD SGA PS ASM W/FRU PACKAGING See Long Description 2334862-2 Part Type: GP REPAIRABLES Part Weight: 2.18 LBR Repairable: Yes Returnable: Yes Hazardous Material: N Description: ACGD SGA PS ASM W/FRU PACKAGING FRU: Yes Status: Orderable This supply is for use with HFD, HFD-S, and ACGD Cabinets. ** WARNING - POSSIBLE PERSONAL INJURY. HEAVY OBJECT - THE POWER SUPPLY WITH CASE WEIGHS APPROXIMATELY 240 LBS (109 KG). Assistance to lift this product mechanical (Dollies) or Additional personnel] is required. 212002950 May 27, 2009
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- TPS/MGD fails to download or reset. mgd_term windows fail to mount file system.
- The Carriage Fails to Advance to Latch to the Table and to Retract When it is Raised, Undocked or Lowered.
- Unable to Load Applications Software during restoreinfo Due to Corrupt saveinfo Disk.
- CWA ID100315. Auto and Manual Prescan Fails.
- Ghosted or Smeared Head Images Using Head Coil due to Head TR Assembly.
- A Copper Coolant Line or Pipe Internal to the MCS Cabinet Chiller Burst due to Water Remaining in Unit Freezing During Shipment.