Pular para o conteúdo principal
GE Healthcare · X-ray VascularInnova107001710700211070657

TSG0059-EMCIO_cable_DCDC troubleshooting 5161658-FRU-DC-DC Conv ASSLY 5150494-FRU-EMCIO

Symptom

IQ+ or PRO table, Table longitudinal (Longi) motion. Table/Gantry speed & range reduced.up IQ+ or PRO table, Table longitudinal motion will cause, Table/Gantry speed & range reduced. Table Longi motion. Table/Gantry speed & range reduced.up. IQ+ or PRO table, Table longitudinal motion will cause, Table/Gantry speed & range reduced.

Error message

1070017 24V err longi DO Table Longi motion. Table/Gantry speed & range reduced. Tilt table: EMCIO_cable_DCDC DC-DC is not giving the power to the EMCIO/AIB/Longi/Lat/Lift/Tilt/RB. Fuse(C2 cabinet) Note: If "1070021/AIB Power supply error" appears then apply the next steps of this procedure and the step ”Check the EMCIO AIB Cable and the AIB” of the TSG0058. If "1070657/24V Remote box power failure error" appears then apply the next steps of this procedure and steps “Check the RB Adapter cable and the Remote Box” of the TSG0063. Axis Longi Lateral Lift Tilt RB AIB EMCIO Supply LED DS7 DS8 DS9 DS10 DS12 DS11 DS6 Supply PIN Pin7 Pin8 Pin9 Pin10 Pin3 Pin2 Pin1 Open the door to view the DC-DC. Check the supply LED on DC-DC board. See the JobCard TSG0059. If LED is ON then go to step 2. IIf LED is OFF then check DS1 for 48V input supply. If LED DS1 is ON, then input is coming to DC-DC board. Replace the DC-DC. If LED DS1 is OFF then DC-DC Board is OFF, incoming supply is not coming to the DC-DC board. Measure the 48 Vdc +/-5% at the C2 MPDU F604 to TB602. If the voltage is in specs then replace the Fuses. Check the Voltage across the input connector J1 on the DC-DC board. The voltage sh

Applies to

Models
Innova
Product
X Innova 2100 Do not use Innova 2100iq System Innova 2100
Software
$ IQ+ or PRO table, ELEGANCE_IS2, DL_ELEGANCE_3.2.1 IQ+ or PRO table, ELEGANCE_IS2, DL_ELEGANCE_3.2.1 IQ+ or PRO table, ELEGANCE_IS2, DL_ELEGANCE_3.2.1
Area
X-ray Vascular

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare X-ray Vascular issues