Low Voltage on the High Voltage SSM Supply.
Symptom
Unable to Scan with SSM HV Power Supply Low Errors. See long description. New install. Unable to do first scan, get one pulse in prescan and then get a "SSM HV power supply low" and an "inductive or direct drive fault. Both faults state possible shorted load. The FE did a diode check on the BCD1, BCD2, and DD drive lines at the rear of the SSM, and read diode on all. FE powered off the SSM and then powered back on and measured OL on the HV test point on the CPFD, and then after about 25 seconds the HV went to 6-7 volts and HVPS fault led lit on the SSM, this happens with or without the BCD1, BCD2, and DD cables connected. This was very repeatable. FE got into the SSM and found the HV would stay up if the HV line to the CPD was disconnected at J5 (red cable) and JP2 in on the HV board and monitoring at TP7 & TP4 on the HV board. Also found a chip on the SSM which had a hole burned through it (don't know the location of this chip). With all of this we have concluded that the CPD is likely the problem. The SSM is the FRU on Excite systems. FE to order the SSM.
Error message
2249163 SSM fault. High voltage power supply low. 2249163 Host: mr01 Process: NSP File: SCP:../RfNbMdsHWO.cpp Line: 2370 Exception Class: Unknown Severity: Unknown Function: RF: RF Bias PSD: Gradient Echo Coil: 8HRBRAIN Scan: 26489/1 SSM fault.^A High voltage power supply low. 2249163 Host: mr01 Process: NSP File: SCP:../RfNbMdsHWO.cpp Line: 2370 Exception Class: Unknown Severity: Unknown Function: RF: RF Bias PSD: Gradient Echo Coil: 8HRBRAIN Scan: 26489/1 SSM fault. High voltage power supply low. 2218537 Scan stopped, Scan Stopped due to error An SSM High Voltage Power Supply Failure Occurred. See long description Mon Nov 3 12:49:08 2008 Error: 2218537 Host: MR-001-BU Process: scn File: MsaScanMgr.m Line: 3038 Scan stopped, Scan Stopped due to error : An SSM High Voltage Power Supply Failure Occurred.. 2218527 Scanning has stopped. SSM High Voltage Supply is not ready. See Long Description Thu May 28 14:55:30 2009 Error: 2218527 Host: vgh mr02 Process: scn File: MsaScanOpsScrn.m Line: 1037 Scanning has stopped. SSM High Voltage Supply is not ready.
Applies to
- Models
- Excite
- Product
- Excite HDx Includes "Excite HDi" system. 14.0 Software only.
- Software
- 14.0 M5 Excite HDx HDi Platforms only.
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- TPS/MGD fails to download or reset. mgd_term windows fail to mount file system.
- The Carriage Fails to Advance to Latch to the Table and to Retract When it is Raised, Undocked or Lowered.
- Unable to Load Applications Software during restoreinfo Due to Corrupt saveinfo Disk.
- CWA ID100315. Auto and Manual Prescan Fails.
- Ghosted or Smeared Head Images Using Head Coil due to Head TR Assembly.
- A Copper Coolant Line or Pipe Internal to the MCS Cabinet Chiller Burst due to Water Remaining in Unit Freezing During Shipment.