GE Healthcare · X-ray VascularInnova500631000014600105100025
Innova: Positioner error.
Positioner error.
Symptom
Innova: Positioner error. Reset system. If problem persists, call Service. X-Ray is inhibited, Lost All Gantry axis's drive or NO movements. Omega table elevation will not drive down. Positioner error. Reset system. If problem persists, call Service. X-Ray is inhibited Positioner error. Reset system. If problem persists, call Service. X-Ray is inhibited, Lost All Gantry axis's drive or NO movements. Omega table elevation will not drive down. Lift failure, dose is minimized, call service
Error message
INX100: 50063 GENERAL POSITIONER MODULE SOFTWARE ERROR ( 4A70 ) Followed by 1000014, 600105 and 100025 Arcnet failures 50063 POS : GENERAL POSITIONER MODULE SOFTWARE ERROR DO VAS / POS (null) Software Problem 1 1 POS ERROR=4A70,HDW STATUS=0031,USR STATUS=0001 XRPAtlasLogger.cpp 99 Followed by 1000014 SID SSD out of range 600105 ARCNET Communication Failure 50063 POS : GENERAL POSITIONER MODULE SOFTWARE ERROR HWStatus=0032 User=0000 0001 4A70
Applies to
- Models
- Innova
- Product
- Innova 2000 Innova 2000 systems Innova 2000 systems
- Software
- $, Innova 2000 Service Pack FMI F4, HerSvcPack_2.02 HerSvcPack_2.02 DL Applications version 11.23.26 Ghost DL-1 "F" : 17.4 Ghost DL-1 "G" : 15.5 Ghost DL-2 : 16.4 Ghost DL-4 : NA DL : 11.23.26 DL Atlas Core : 3.1O-1 RTAC Atlas Core : 3.1O-2 IDC : 2.13 Calypso : 11.13_FMI_7 Calypso Uptime : 11.25_FMI Titan : H0.57 Pos. Motorola : 5.2Y3-2 Pos. Roadrunner : 5.0R
- Component
- CPU Roadunner in the Positioner CPU Roadunner in the Positioner. Check FeTools and ASM for any updates on part numbers. Aways load SW on new board. Part #: 5145126 Part Type: GP CONSUMABLE - RETURNABLE Part Weight: 2.43 LBR Repairable: No Returnable: Yes Hazardous Material: N Description: RP CPU ROADRUNNER CVC FRU: Yes Status: Orderable CPU Roadunner in the Positioner. Check FeTools and ASM for any updates on part numbers. When replacing CPU, Aways load SW on new board. Part #: 5145126 Part Type: GP CONSUMABLE - RETURNABLE Part Weight: 2.43 LBR Repairable: No Returnable: Yes Hazardous Material: N Description: RP CPU ROADRUNNER CVC FRU: Yes Status: Orderable
- Area
- X-ray Vascular
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray Vascular issues
- The Worklist does not refresh on the system when performing a query.
- Innova System boot failure
- INX1X; Message Limit switch engaged; LP4 Lateral Detector lift will not move after going to max SID using the Emergency Backout button on the lift cover because the lift hit maximum (Max) SID limit sw…
- Firewall is broadcasting DHCP addresses
- Cooling Failure; Shut System down and call Service is displayed on the Innova Image monitor
- No gantry motion is reported by the customer.