GE Healthcare · MRSignaExcite2225550222569922255382225704
Unstable Buck Convert / H Bridge Power Supply in SSM.
Symptom
Can Not Scan
Error message
2225550 Multi-coil array driver error. A write to the multi-coil array driver coil register failed to verify See Long Description 2225550 Host: LX_MR1 Process: NSP File: HPC_PORT_ID:spi_tr_mon Line: 6300 Multi-coil array driver error.^A A write to the multi-coil array driver coil register failed to verify. Possible causes: bad board or connections in the TR chassis. 2225699 MDS link failure. An MDS device failed to respond to IPG on a 2nd try. If the link is broken, a separate error message will be logged. If not, a spurious error occurred. Timer: 509 MDS header: 0x11 -(00/10 = Grad, 01/11 = RF Cab) MDS opcode: 0x0B 2225699 lx-mr NSP HPC_PORT_ID:spi_mds 509 MDS link failure. An MDS device failed to respond to IPG on a 2nd try. If the link is broken, a separate error message will be logged. If not, a spurious error occurred. Timer: 509 MDS header: 0x11 -(00/10 = Grad, 01/11 = RF Cab) MDS opcode: 0x0B 2225538 T/R driver indicates it is no longer in a normal mode of operation. 2225538 lx-mr NSP HPC_PORT_ID:spi_tr_mon 6245 T/R driver indicates it is no longer in a normal mode of operation. 2225704 MDS link failure. The MDS fiber optic link appears to be broken between the RF and Sys
Applies to
- Models
- Signa, Excite
- Product
- Signa LX Signa LX Product can be used with 8.x and 9.x systems.
- Software
- 9.1 For Signa LX product only
- Component
- SecondOpinion System Support Module 2160200-43 See comments in resolution concept for second opinion requirements before ordering this part. FE replaced SSM which is now a FRU Part #: 2160200-43 Part Type: GP REPAIRABLES Part Weight: 48.50 LBR Repairable: Yes Returnable: Yes Hazardous Material: N Description: ERBTEC #550020 SYSTEM SUPPORT MODULE FRU: Yes Status: Orderable ICV/Transfer Price: 5684.00 USD /Each List Price: 36215.22 USD /EACH See comments in resolution concept for second opinion requirements before ordering this part. FE replaced SSM which is now a FRU Part #: 2160200-43 Part Type: GP REPAIRABLES Part Weight: 48.50 LBR Repairable: Yes Returnable: Yes Hazardous Material: N Description: ERBTEC #550020 SYSTEM SUPPORT MODULE FRU: Yes Status: Orderable ICV/Transfer Price: 5684.00 USD /Each List Price: 36215.22 USD /EACH
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- Running grafidy3, and find there are spikes on the waveforms in the manual prescan display, both windows.
- TPS/MGD fails to download or reset. mgd_term windows fail to mount file system.
- Fails to Scan with TORSO Coil.
- The Carriage Fails to Advance to Latch to the Table and to Retract When it is Raised, Undocked or Lowered.
- AE title has changed on destination host.
- Unable to Load Applications Software during restoreinfo Due to Corrupt saveinfo Disk.