Pular para o conteúdo principal
GE Healthcare · MRExciteSigna2244570221852722450535952822448512244577

MRIQ Corduroy Artifact and Gradient Amplifier X-Axis Current Distortion Fault due to BRM-D.

Symptom

MRIQ Corduroy Artifact and Gradient Amplifier X-Axis Current Distortion Fault See Long Description and Attachment 1.5T Excite HD system running 12.0 M5B software experiencing corduroy artifact on all coils as well as Gradient Amplifier X Axis Current Distortion Fault when running Gradient Driver diagnostics. See Attachment for errors and an example image.

Error message

2244570 The gradient amplifier failed to go to Ready when commanded. 2244570 TOiMR2 NSP SCP:Grad 1106 Exception Class: Unknown Severity: Unknown Function: Gradient: N/A PSD: Spin Echo Coil: US SHOULDER PA Scan: 379/4 The X Axis gradient amplifier failed to go to Ready when commanded.-> 2244570 TOiMR2 NSP SCP:Grad 1106 Exception Class: Unknown Severity: Unknown Function: Gradient: N/A PSD: Spin Echo Coil: US SHOULDER PA Scan: 379/4 The X Axis gradient amplifier failed to go to Ready when commanded.

2218527 Scanning has stopped. Master Gradient is not ready 2218527 lx-mr scn MsaScanOpsScrn.m 916 Scanning has stopped. Master Gradient is not ready.

2245053 GRADIENT DRIVER TESTS - The GP is reporting a Gradient Amplifier % Axis Current Distortion Fault. Ready Static Mode-> 2245053 lx-mr diagCoord grad_lib.c 921 Diagnostic: GDT Static Iteration: 1 of 1 Action: 1 Task ID: 0x3d5c6c8 Time: 59528 Object: SCP Test Task GRADIENT DRIVER TESTS - The GP is reporting a Gradient Amplifier % Axis Current Distortion Fault. Ready Static Mode->

2244851 The GP is reporting a Gradient Amplifier %c Axis Current Distortion Fault. the same error as 2244577 on 11X, G3, openMR4 and 2244578 on 12X, E2, 14M4

Applies to

Models
Excite, Signa
Product
Excite HD For 12.0 1.5T Systems only.
Software
12.0 Excite HD and 3T Excite HD products only
Component
SecondOpinion BRM-D 2144093-5 See long description for SMILe on returning BRM's. See comments in resolution concept for second opinion requirements before ordering this part SMILe 2/7/2006 Subject: Failed and unused BRM coils must be returned promptly for evaluation and repair. Effectivity: All Signa 1.5T Horizon, LX, EXCITE and HD MR systems. Problem: Unused BRM's are remaining on site too long which severely limits the availability of FRU BRM coils. The repair facility is able to perform quick evaluations/repair of coils but BRM's must be returned promptly. Resolution: BRM coils should be ordered with no more than a 3-day lead time . Every effort is being made to always have FRU BRM's available but your help is needed. Within 10 days of shipment of the FRU BRM either it or the failed unit must be returned. Any exceptions to this time limit must be cleared through Ramamohan Pai, Global Modality Leader-MR & XR. Email : [email protected] Tel: 1-262-544-3240, Dial Com : 320-3240
Area
MR

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare MR issues