SN4879, ADV & Innova, New flexible tube water hose installation.
Symptom
SN4879, ADV & Innova, New flexible tube water hose installation. SN4879, ADV & Innova new flexible tube water hose installation. Rev.1 5341819-8EN APPLIES TO All water hoses from C-Arc to Tube implanted in Frontal (LC) positionner. Impacted systems: Advantx–E, Innova monoplane and biplane. SN4879, ADV & Innova new flexible tube water hose installation. APPLIES TO All water hoses from C-Arc to Tube implanted in Frontal (LC) positionner. Impacted systems: Advantx–E, Innova monoplane and biplane. PURPOSE/SYMPTOM A premature locking of the water coupling rotation can occur, leading to a water leakage in the Carc sleeve. This failure can be increased by the presence of the stiffener rod. In order to prevent this problem from happening, new water hoses have been implemented on Monoplane and Biplane forward production. This has been implemented on May 2009 in Buc Mfg. Flexible water hoses are backward compatible on the Installed Base and replace some actual FRU. RECOMMENDATIONS 1. The stiffener shall NOT be installed on any system that is equipped with the water coupling (2184070-2 “RP ROTATING GASKET”). This applies to Monoplane & Biplane systems produced after 24–Oct-2008. This can also happen for monoplane systems produced before November 2007, which did not have the stiffener. 2. The stiffener shall be installed ONLY with the flexible water hoses (5332506 “FRU Kit Swivel Elbow-V2 + Water Hose” & 5332507 “Ulysse Water Hose”). Flexible water hoses FRU REPLACEMENT The flexible water hoses are located at the same place as the original system (see picture below). It is backward compatible on the Installed Base. The flexible water hoses Part Number are 5332506 and 5332507. They replace current Part Numbers 2129844, 2129844-2, 2349492, 2349497, 2184070, 2184070-2, and 5304327. These parts will not continue to be used for the Installed Base. Two flexible hoses replace 1 “rotating gasket” + 1 “assembly rigid water hose” + 2 “flexible water hoses with tube coupling”
Applies to
- Models
- Innova, Advantx
- Product
- Innova X100 Monoplane Innova X100 Monoplane from product name Innova 2100, 3100 and 4100 Innova X100 Monoplane Innova 2100, 3100 and 4100
- Software
- $ Unity M4 SP3.2 DL_Unity_4.18.9, FMI 12105 Unity M4 SP3.2 DL_Unity_4.18.9 FMI 12105 Unity M4 SP3.2 DL_Unity_4.18.9, FMI 12105 healthpage tag for this software is UNITY_M4_FMI_4.21 212009270 03/26/2010 13:31 GMT
- Area
- X-ray Vascular
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray Vascular issues
- The Worklist does not refresh on the system when performing a query.
- Innova System boot failure
- INX1X; Message Limit switch engaged; LP4 Lateral Detector lift will not move after going to max SID using the Emergency Backout button on the lift cover because the lift hit maximum (Max) SID limit sw…
- Firewall is broadcasting DHCP addresses
- Cooling Failure; Shut System down and call Service is displayed on the Innova Image monitor
- No gantry motion is reported by the customer.