Pular para o conteúdo principal
GE Healthcare · MR

Compressor Will Not Start Up.

Symptom

LCC Alarm Failed To Reset Compressor. LCC Alarm Failed To Reset Compressor, the SHeM attempted to reset the shield cooler compressor but was unsuccessful.

Error message

LCC Alarm Failed To Reset Compressor. LCC Alarm Failed To Reset Compressor, the SHeM attempted to reset the shield cooler compressor but was unsuccessful.

Applies to

Product
Magnet Monitor SHeM Advantech. Part Number: 2219400 (OBSOLETE, changes up to a MM3, 2394952 as of July, 2006) Modem Cable: 2276568 MultiTech Modem: 2245794 Magnet Monitor Proprietary Software: 2252032-3 See the Long Description for the link to download the following 4 manuals; LCC Magnet Mon. Hardware Install: 2230681 LCC ProActive Software Install & T/S: 2236995 HFO Magnet Mon. Hardware Install: 2261116 HFO ProActive Software Install & T/S: 227721 Proprietary, For GE Healthcare personnel Only This information is Property of GE Healthcare - For GE Healthcare Service Personnel Only. Disclosure to Third Parties Prohibited. Click on this link to reach the Magnet Service Documentation CD-Rom on the MR Engineering Service Documentation website. Part Number : 2219400 ( OBSOLETE , changes up to a MM3, 2394952 as of July, 2006 ) Modem Cable : 2276568 MultiTech Modem : 2245794 Magnet Monitor Proprietary Software : 2252032-3 The following 4 manuals may be downloaded from the above Magnet CD-Rom link. LCC Magnet Mon. Hardware Install: Direction 2230681 LCC ProActive Software Install & T/S: Direction 2236995 HFO Magnet Mon. Hardware Install: Direction 2261116 HFO ProActive Software Install & T/S: Direction 2277211
Software
SHeM Proprietary Software 2.3.7. SHeM Proprietary Software 2.3.7 SHeM Proprietary Software 2.3.7.
Component
SecondOpinion Part Number 2188440-2 Sumitomo CSW Series 4K and 10K Compressor. The Sumitomo 4K and 10K Compressor is the same Unit. Sumitomo compressor 2188440-2 is the same for both 10K and 4K Sumitomo cryo-cooler systems. See Long Description for FEMC Comments and Resolution concept for Second Opinion requirements before ordering this part. See comments in Resolution concept for Second Opinion requirements before ordering this part. FEMC Comments: FLS - COMPRESSOR USED ON SHI 10K SYSTEM REPLACES 2188440 PER PCN 188657. COMPLETELY INTERCHANGEABLE AND BOTH CAN BE COMBINED IN THE SAME POOL PER G. BUTLER 2-14-00, A. MASCH FOR GREEN SOURCE DIRECTLY FROMSUMITOMO JAPAN +++ For hour meter issues please order - 2191112-8. +++ *** 2ND OPINION NOTES *** This part has been identified as one requiring second opinion approval before ordering due to one or more of the following reasons: High cost. For approval: Americas - Contact: OnLine Center or your ZSE Europe - OnLine Center or your ZSE Asia - Contact the OnLine Center or your Technical Support. 212002950 April 28, 2008.
Area
MR

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare MR issues