GE Healthcare · X-ray VascularInnova105027810500821050187
The Omega table elevation will not drive down vertically.
Symptom
The Omega table elevation will not drive down vertically. When the customer selects the down elevator motion, the enable works, but the table does not lower. The elevator up function is normal. The Omega table top will not drive down vertically. When the customer selects the down elevator motion, the enable works, but the table does not lower. The elevator up function is normal.
Error message
Omega, CPU-STEPPER board com issue: error 1050278, With 1050082 debug "PIB: 24V table PRD failed" 1050187 TBLROT COMM LOST DO Table (null) TBLROT_COMM_LOST 0 0 - Communication lost with table rotation encoder switching to degraded mode (T:4B14 H:0x000B U:0x0000) and 1050082 PIB 24V TBL POWER WR Positioner Power 0 PIB_24V_TBL_POWER 0 0 - PIB: 24V table PRD failed Z:/heroic/pib_task.c 1806
Applies to
- Models
- Innova
- Product
- Innova X1 X1 Biplane Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System Innova X100 Monoplane Innova X100 Monoplane from product name Innova 2100, 3100 and 4100 Innova X100 Monoplane Innova 2100, 3100 and 4100 Innova 2000 Innova 2000 systems Innova 2000 systems
- Component
- Omega IV Cardiac table Omega IV Cardiac table Omega IV cardiac table Omega V Table Omega V Table Omega V Table Innova 2100–IQ Case Innova 2100–IQ System can be supplied with an OMEGA IV Compact patient table, an OMEGA V long patient table, which includes a table side control with Contour Filter, or a InnovaIQ patient Table. Innova 3100/3100-IQ and 4100/4100-IQ Case Innova 3100/4100 Systems can be supplied with an OMEGA V Long patient table or InnovaIQ patient Table, which includes a table side control with Contour Filter. Illustration 2-1: Omega patient table (with TSSC)
- Area
- X-ray Vascular
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray Vascular issues
- The Worklist does not refresh on the system when performing a query.
- Innova System boot failure
- INX1X; Message Limit switch engaged; LP4 Lateral Detector lift will not move after going to max SID using the Emergency Backout button on the lift cover because the lift hit maximum (Max) SID limit sw…
- Firewall is broadcasting DHCP addresses
- Cooling Failure; Shut System down and call Service is displayed on the Innova Image monitor
- No gantry motion is reported by the customer.