The Innova console displays Digital or keypad failure, reset system and call Service

Symptom

IN2K: The Innova console displays Digital or keypad failure, reset system and call Service The Innova console displays Digital or keypad failure, reset system and call Service. 2800015 "Due to a possible communication error detected with PDU, power supply is not controlled" 1. Run DL subsystem/ Interactive/PDU diagnostics. 2. If no error found then replace ATLAS PDU 4KVA WITH AC REG- WITH UPS 2800013 Due to a possible hardware error detected with PDU, power supply is not controlled" 1. Run DL subsystem/ Interactive/PDU diagnostics. 2. If no error found then replace ATLAS The Innova console displays Digital or keypad failure, reset system and call Service May see in error log for Innova 2000 2800015 "Due to a possible communication error detected with PDU, power supply is not controlled" Run DL subsystem/ Interactive/PDU diagnostics. If no error found then replace ATLAS PDU 4KVA WITH AC REG- WITH UPS 2800013 Due to a possible hardware error detected with PDU, power supply is not controlled" Run DL subsystem/ Interactive/PDU diagnostics. If no error found then replace ATLAS PDU 4KVA WITH AC REG- WITH UPS 2800016 "Due to a possible hardware error detected with the local Keypad, local Keypad is not available" Run DL subsystem/Interactive/ Zephir serial diagnostics with loopback succesively on DL and on cable. If no error found, then replace DLX KEYPAD

Error message

2800013 WR XRSubSysMgrDL Due to a possible hardware error detected with PDU, power supply is not controlled Debug: event:PDU failure --> Low Battery

Applies to

Models
Innova
Product
Innova 2000 Innova 2000 systems Innova 2000 systems
Software
$, Innova 2000 Service Pack FMI F4, HerSvcPack_2.02 HerSvcPack_2.02 DL Applications version 11.23.26 Ghost DL-1 "F" : 17.4 Ghost DL-1 "G" : 15.5 Ghost DL-2 : 16.4 Ghost DL-4 : NA DL : 11.23.26 DL Atlas Core : 3.1O-1 RTAC Atlas Core : 3.1O-2 IDC : 2.13 Calypso : 11.13_FMI_7 Calypso Uptime : 11.25_FMI Titan : H0.57 Pos. Motorola : 5.2Y3-2 Pos. Roadrunner : 5.0R
Area
X-ray Vascular