GE Healthcare · X-ray VascularInnova10501711050513105050110505921050148
INX100, Lost All Gantry axis's drive or NO movements
Symptom
INX100, Lost All Gantry axis's drive or NO movements The Gantry axis's will not drive. The Innova Gantry is locked and will not drive the L-arm, Pivot, Arc, or Lift. Emergency backout works, L-arm clutch releases. Gantry Problem: reset the system to recover is displayed on the monitor The Gantry axis' will not drive. The Innova Gantry is locked and will not drive the L-arm, Pivot, Arc, or Lift. Emergency backout works, L-arm clutch releases. Gantry Problem: reset the system to recover is displayed on the monitor
Error message
INX1X1, 1050171 VXWORKS error Debug - Movements limited at half speed cause the ramp management module can't update ramps 1050171 VXWORKS error Debug - Movements limited at half speed cause the ramp management module can't update ramps. Lat off park location May see from this error. 1050513, Lat: LAT PIVOT AXIS POWER, No Motion, Lat_Pivot_AXIS_POWER, 0, 0, - vinputNotDetected 1050501, Lat: LAT BUDDY PIVOT AXIS ENABLE, No Motion, Lat_BUDDY_Pivot_AXIS_ENABLE, 0, 0, - disableFromBuddyN 1050592, Lat: LAT CARRIAGE AXIS SWITCH ENGAGED, No Motion, Lat_Carr_AXIS_SWITCH_ENGAGED, 0, 0, - mcbLimitSwitch 1050148, ERR MISCELLANEOUS, Frt_ERR_MISCELLANEOUS, 0, 0, - Rall position not attained 1050592, Lat: LAT CARRIAGE AXIS SWITCH ENGAGED, No Motion, Lat_Carr_AXIS_SWITCH_ENGAGED, 0, 0, - Extra course switch engaged or 24V failure (4AB6) 1050513, CLEAR 1050501, CLEAR 1050148, CLEAR
Applies to
- Models
- Innova
- Product
- Innova X100 Monoplane Innova X100 Monoplane from product name Innova 2100, 3100 and 4100 Innova X100 Monoplane Innova 2100, 3100 and 4100
- Area
- X-ray Vascular
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray Vascular issues
- The Worklist does not refresh on the system when performing a query.
- Innova System boot failure
- INX1X; Message Limit switch engaged; LP4 Lateral Detector lift will not move after going to max SID using the Emergency Backout button on the lift cover because the lift hit maximum (Max) SID limit sw…
- Firewall is broadcasting DHCP addresses
- Cooling Failure; Shut System down and call Service is displayed on the Innova Image monitor
- No gantry motion is reported by the customer.