GE Healthcare · MRExcite2252360707272252132
TPS Download Fails with SCP Errors and Driver Module Diagnostic Errors Due to Driver Module.
Symptom
Unable to Download or Reset the TPS MGD or ISE Unable to download TPS or ISE or MGD chassis
Error message
2252360 The Driver Module did not detect the T/R DD board, which is required Error: 2252360 Host: MR03 Process: diagCoord File: CanDriverHWO Line: 2721 Diagnostic: DCB Diag Iteration: 1 of 1 Action: 1 Task ID: 0x3156958 Time: 70727 Object: SCP T/R DD Board Not Detected. The Driver Module did not detect the T/R DD board, which is required. Please make sure the board is present and perform a TPS reset.-> Extended Error: 2252360 ERROR: EM_SCP_TRDD_NOT_PRESENT T/R DD Board Not Detected. The Driver Module did not detect the T/R DD board, which is required. Please make sure the board is present and perform a TPS reset. Possible cause(s): Driver Module 2252132 PDO Communication Failure was detected on the CANopen Protocol Node Detecting Failure = SCP Wed Aug 25 08:04:47 2004 2252132 2 MR-OC0 NSP SCP:NodeData 1128 PDO Communication Failure was detected on the CANopen Protocol. Node Detecting Failure = SCP. Node ID = 2. PDO Number = 3. Error Code = 0x1002.-> SCP_Boot Server Init Error SCP application startup failed SCP window error. SCP_Boot Server Init Error SCP application startup failed. Can Encountered an Error during startup Error in SCP boot up window
Applies to
- Models
- Excite
- Product
- Excite HD For 12.0 1.5T Systems only.
- Software
- 12.0 Excite HD and 3T Excite HD products only
- Component
- SecondOpinion Excite HD & HDx Driver Module 5110612-2 See comments in resolution concept for second opinion requirements before ordering this part
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- TPS/MGD fails to download or reset. mgd_term windows fail to mount file system.
- The Carriage Fails to Advance to Latch to the Table and to Retract When it is Raised, Undocked or Lowered.
- Unable to Load Applications Software during restoreinfo Due to Corrupt saveinfo Disk.
- CWA ID100315. Auto and Manual Prescan Fails.
- Ghosted or Smeared Head Images Using Head Coil due to Head TR Assembly.
- A Copper Coolant Line or Pipe Internal to the MCS Cabinet Chiller Burst due to Water Remaining in Unit Freezing During Shipment.