GE Healthcare · X-ray VascularInnova14003001400001140000214000191800019
INX1X1, Innova Biplane Boot Failure, Simpte Pattern is displayed.
Innova Biplane Boot Failure, Simpte Pattern is displayed.
Symptom
INX1X1, Innova Biplane Boot Failure, Simpte Pattern is displayed. Message on Monitor is "Reset System, Boot Failure" INX1X1, Boot Failure, Simpte Pattern is displayed. Message on Monitor is "Reset System, Boot Failure" Innova Biplane Boot Failure, Simpte Pattern is displayed. Message on Monitor is "Reset System, Boot Failure"
Error message
1400300 Frontal: DIPB power up tests failure, followed by 1400001, 1400002, 1400019, 1800019 1400300 Frontal: DIPB power up tests failure; IH, [FPGA_Driver::DIPB_init] failed to initialize DIPB 1400001 Front: Software error IH; [SystemInterfaceBoardDriver::readHwConfigParameters] BOARD_TYPE (NONE) unknown 1400002 Front: Operationg system error IH; [ImageAcquisitionMonitoring::ImageAcquisitionMonitoring] Unable to get instance of Gitane Driver 1400019 Front: Software error DO; [Preprocessi 1400300 Frontal: DIPB power up tests failure, followed by 1400001, 1400002, 1400019, 1800019 1400300 Frontal: DIPB power up tests failure; IH, [FPGA_Driver::DIPB_init] failed to initialize DIPB 1400001 Front: Software error IH; [SystemInterfaceBoardDriver::readHwConfigParameters] BOARD_TYPE (NONE) unknown 1400002 Front: Operationg system error IH; [ImageAcquisitionMonitoring::ImageAcquisitionMonitoring] Unable to get instance of Gitane Driver 1400019 Front: Software error DO; [PreprocessingDriver::getInstance] IP_BOARD_TYPE(NONE) is not recognized 1800019 Front: Software error DO; [DigAbdDriver::getInstance] IP_BOARD_TYPE(NONE) is not recognized; assuming DIPB by default
Applies to
- Models
- Innova
- Product
- Innova X1 X1 Biplane Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System
- Software
- $ M4 SPAD BIP_4.18.5, DL_SPAD_4.15.1 FMI 12108 $New, M4 SPAD BIP_4.18.5, DL_SPAD_4.15.1 FMI 12108 or $ new, Innova Biplane M4 BIP_4.18.5, DL_4.15.1 FMI 12108 $New, M4 SPAD BIP_4.18.5, DL_SPAD_4.15.1 FMI 12108 or $ new, Innova Biplane M4 BIP_4.18.5, DL_4.15.1 FMI 12108
- Area
- X-ray Vascular
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray Vascular issues
- The Worklist does not refresh on the system when performing a query.
- Innova System boot failure
- INX1X; Message Limit switch engaged; LP4 Lateral Detector lift will not move after going to max SID using the Emergency Backout button on the lift cover because the lift hit maximum (Max) SID limit sw…
- Firewall is broadcasting DHCP addresses
- Cooling Failure; Shut System down and call Service is displayed on the Innova Image monitor
- No gantry motion is reported by the customer.