Unable to Run Automated DQA Calibration Tool.
Symptom
Unable to Run Automated DQA Calibration Tool See Long Description and Attachment. It Fails With Error Message "Wrong imaging parameters for Isocenter-Z calibration" or "Wrong imaging parameters for Gradient [X or Y or Z] field calibration" iTrak #s 13155738 and 13154170: The Automated DQA Calibration Tool opens normally with a menu selection of Auto or Manual. The tool then presents a choice of Isocenter-Z, or Gradient X, Y, Z or ALL. Following proper set-up for the coil and DQA phantom, the tool configures the scan for the selected mode and scans. The Automated DQA Calibration Tool then gives the following error depending on the mode selected: (See Attachment for a screenshot) Wrong Imaging Parameters for Isocenter-Z calibration FOV: 24cm Acq. Matrix: Freq. ->512, Phase->256 Freq. Direction: A/P Wrong Imaging Parameters for Gradient [X or Y or Z] field calibration FOV: 24cm Acq. Matrix: Freq. ->512, Phase->256 Freq. Direction: X=L/R, Z=A/P, Y=A/P Also, on a related note, after completion of SPT, there are no results reported at the end. By selecting the “WhatFailed” button on the bottom right of the SPT window, the following message appears: "Unable to find/open the output file." The SPT results can be viewed normally through Report Manager with the corresponding PASS, MARGINAL, SEVERE status
Error message
Application to invoke remote service are not running.
Applies to
- Models
- Excite
- Product
- Excite Includes Excite 1 and Excite 2, 10.0, 11.0 and 11.1 Software.
- Software
- 11.0 Only for 1.5T Excite product. 12.0 is Excite HD and 14.0 is Excite HDx. Note, 3T Excite goes with software G3, not 11.0 or 11.1.
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- TPS/MGD fails to download or reset. mgd_term windows fail to mount file system.
- The Carriage Fails to Advance to Latch to the Table and to Retract When it is Raised, Undocked or Lowered.
- Unable to Load Applications Software during restoreinfo Due to Corrupt saveinfo Disk.
- CWA ID100315. Auto and Manual Prescan Fails.
- Ghosted or Smeared Head Images Using Head Coil due to Head TR Assembly.
- A Copper Coolant Line or Pipe Internal to the MCS Cabinet Chiller Burst due to Water Remaining in Unit Freezing During Shipment.