Scan Pause with Gradient Internal Wiring Fault and Data Over range Errors recovers on its own and Images Show White Line…
Scan Pause with Gradient Internal Wiring Fault and Data Over range Errors recovers on its own and Images Show White Lines Due to STIF Board.
Symptom
Scan Pause with Gradient Internal Wiring Fault and Data Over range Errors recovers on its own and Images Show White Lines See long description Mon May 25 16:04:37 2009 2248108 4 lxmr NSPAPS:dataMoverTask 591APS received data over range error from DRF, on chan = 0 Need to reduce receiver gain. Mon May 25 16:04:37 2009 2224666 1 lxmr pscPscMainControl.cc 1351Auto Prescan failed, Asynchronous stop scan. Mon May 25 16:04:37 2009 2244847 2 lxmr NSPSCP:Grad 2596The GP reported a Gradient Amplifier Y Axis Internal Wiring Fault or Control Undervoltage.->
Error message
2244847 The GP reported a Gradient Amplifier % Axis Internal Wiring Fault or Control Undervoltage Error: 2244847 Host: SEMRADMR2 Process: NSP File: SCP:Grad Line: 2615 Exception Class: Unknown Severity: Unknown The GP reported a Gradient Amplifier X Axis Internal Wiring Fault or Control Undervoltage. 2224666 Auto Prescan failed, Asynchronous stop scan. 2248108 APS received data over range error from DRF, on chan= n. 2248108 TOiMR2 NSP APS:dataMoverTask 604 Exception Class: Idle Severity: Unknown Function: Acquisition/Pulse Generation: Acquisition PSD: Spin Echo Coil: US SHOULDER PA Scan: 379/4 APS received data over range error from DRF, on chan = 2 Need to reduce receiver gain.
Applies to
- Models
- Excite
- Product
- Excite HD For 12.0 1.5T Systems only.
- Software
- 12.0 Excite HD and 3T Excite HD products only
- Component
- 2280952-3 STIF Board See Long Description SRF TRF I/O or STIF 2280952 crosses up in FEMC to 2280952-3. Part Description is "STIF Assembly".
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- TPS/MGD fails to download or reset. mgd_term windows fail to mount file system.
- The Carriage Fails to Advance to Latch to the Table and to Retract When it is Raised, Undocked or Lowered.
- Unable to Load Applications Software during restoreinfo Due to Corrupt saveinfo Disk.
- CWA ID100315. Auto and Manual Prescan Fails.
- Ghosted or Smeared Head Images Using Head Coil due to Head TR Assembly.
- A Copper Coolant Line or Pipe Internal to the MCS Cabinet Chiller Burst due to Water Remaining in Unit Freezing During Shipment.