GE Healthcare · MRSignaHiSpeedExcite2262606225231851384224860222259352261230
CWA ID138083. PDU was in stop mode.
Symptom
PDU in Stop Mode and TPS Download failure
Error message
2262606 The PHPS was not detected on the system CAN bus 2262606 The PHPS was not detected on the system CAN bus.-> 2252318 Exception Class The Driver Module Has Detected a Power Supply Fault Source of Fault is High Voltage Power Supply. Fri Apr 7 08:18:07 2006 Error: 2252318 Host: b5 Process: NSP File: SCP:DCB Line: 1355 Exception Class: Unknown Severity: Unknown Function: RF: RF Bias PSD: Vasc TOF Coil: HEAD Scan: 51384/3 The Driver Module Has Detected a Power Supply Fault. Source of Fault is High Voltage Power Supply. Actual Voltage = 10.0 Limit Voltage = 950.0-> 2248602 PDU in Stop Mode. Emergency Stop button was pressed or PDU 24 Volt supply has failed. 2248602 PDU is in Stop mode. Emergency Stop button was pressed or PDU 24 Volt supply has failed. 2225935 The PAC does not respond. Check PAC power and fiberoptic connections, run PAC diags. 2225935 The PAC does not respond. Check PAC power and fiber optic connections, run PAC diags. This error condition adversely affects gated scans only. 2225935 The PAC does not respond. Check PAC power and fiberoptic connections, run PAC diags. This error condition adversely affects gated scans only. 2261230 The SCP received an unknown fre
Applies to
- Models
- Signa, HiSpeed, Excite
- Product
- Signa HDxT This product is for 1.5T Signa HDxT systems with 15.0 software and HDi systems with 15.0 software. This product is for 1.5T Signa HDxT systems with 15.0 software and HDi systems with 15.0 software.
- Software
- 15.0 For Product Signa HDxT and HDi only. -- NOT to be used with HDe. -- For Product Signa HDxT and HDi only. -- NOT to be used with HDe. --
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- Running grafidy3, and find there are spikes on the waveforms in the manual prescan display, both windows.
- TPS/MGD fails to download or reset. mgd_term windows fail to mount file system.
- Fails to Scan with TORSO Coil.
- The Carriage Fails to Advance to Latch to the Table and to Retract When it is Raised, Undocked or Lowered.
- AE title has changed on destination host.
- Unable to Load Applications Software during restoreinfo Due to Corrupt saveinfo Disk.