SMART HANDLE CONTROL PROBLEM IS DISPLAYED ON THE IMAGE REVIEW MONITOR
Symptom
IN2K: SMART HANDLE CONTROL PROBLEM IS DISPLAYED ON THE IMAGE REVIEW MONITOR Smart handle control problem, check it or call service is displayed on the image review monitor. On unity software the message is : !SMART HANDLE PROBLEM. CALL SERVICE
Error message
error Code = 50125, hw-status=00A6, HWStatus=00C5 error Text = POS TSUI: SMB or SMH error, debug Text += pos-error=4ACA, hw-status=00A6, recovery Class = DO, major Function /= LC Gantry System impact: Permanent enable. Displayed message : None. error Code = 50125, hw-status=00A6, HWStatus=00C5 error Text = POS TSUI: SMB or SMH error, debug Text += pos-error=4ACA, hw-status=00A6, recovery Class = DO, major Function /= LC Gantry HW A6 = SH master - Permanent enable: TABLE DRIVING ENABLE (longitudinal & up/down) System impact: Permanent enable. Displayed message : None. error Code = 50125, hw-status=00A6, error Text = POS TSUI: SMB or SMH error, debug Text += pos-error=4ACA, hw-status=00A6, recovery Class = DO, major Function /= LC Gantry HW A6 = SH master - Permanent enable: TABLE DRIVING ENABLE (longitudinal & up/down) 50125 DO POS POS : TSUI: SMB OR SMH ERROR Debug: fct-status=0 hw-status=c5 pos-error=4aca usr-status=0 HWStatus=00C5 User=0000 0000 4ACA Smart Box Permanent enable, Gantry motion enable (c-arc & Pivot) Our Error and Solutions Details. 50125 TSIU Permanent Validation. 4ACA HW 00CD. 4ACA HW 00CD is a Permanent Validation on the LARM Control. The table pad was pushing on
Applies to
- Models
- Innova
- Product
- Innova 2000 Innova 2000 systems Innova 2000 systems
- Software
- $, Innova 2000 Service Pack FMI F4, HerSvcPack_2.02 HerSvcPack_2.02 DL Applications version 11.23.26 Ghost DL-1 "F" : 17.4 Ghost DL-1 "G" : 15.5 Ghost DL-2 : 16.4 Ghost DL-4 : NA DL : 11.23.26 DL Atlas Core : 3.1O-1 RTAC Atlas Core : 3.1O-2 IDC : 2.13 Calypso : 11.13_FMI_7 Calypso Uptime : 11.25_FMI Titan : H0.57 Pos. Motorola : 5.2Y3-2 Pos. Roadrunner : 5.0R
- Area
- X-ray Vascular
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray Vascular issues
- The Worklist does not refresh on the system when performing a query.
- Innova System boot failure
- INX1X; Message Limit switch engaged; LP4 Lateral Detector lift will not move after going to max SID using the Emergency Backout button on the lift cover because the lift hit maximum (Max) SID limit sw…
- Firewall is broadcasting DHCP addresses
- Cooling Failure; Shut System down and call Service is displayed on the Innova Image monitor