GE Healthcare · X-ray VascularInnova1050187
Angulation not displayed when reviewing on AW Innova sequences
Symptom
INX1PRO-IQ+: Angulation not displayed when reviewing on AW Innova sequences INX1PRO-IQ+: Angulation not displayed when reviewing Innova sequences on AW. When reviewing the sequence on DL, the angulation is displayed during the review on the DL image monitor. The sequence can be pushed without problem on AW workstation. But when reviewing the sequence on AW, angulation is not displayed during review on AW image monitor.
Error message
1050187 Table Rotation encoder Comm lost Error 1050187 Table Rotation encoder communication lost. See long description for further details. Error 1050187 Table Rotation encoder communication lost. In the errlog, we get the following error: Positioner CPU does not get anymore table rotation value. As a side effect, you may get following error after a record acquisition: This means that a data from positioner was either missing or out of range.
Applies to
- Models
- Innova
- Product
- X Innova 2100 Do not use Innova 2100iq System Innova 2100
- Software
- $ INX1PRO or IQ+,Harmony_M3 INX1PRO or IQ+, Harmony_M3 Product is called INX1PRO or IQ+: Harmony_M3 sw release applicable to Harmony systems.
- Component
- Panthera II Positioner CPU Panthera II Positioner CPU FRU reference 5265361 Panthera II Positioner CPU FRU reference 5265361 Always use the most appropriate documentation for your system. The following reference number was taken from Direction 5311070-2-2EN, Rev# 4 and is provided for your reference from the Innova 2100-IQ, 3100-IQ, 4100-IQ Harmony DVD documentation. To view the most recent appropriate and detailed documentation, go to MY WORKSHOP
- Area
- X-ray Vascular
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray Vascular issues
- The Worklist does not refresh on the system when performing a query.
- Innova System boot failure
- INX1X; Message Limit switch engaged; LP4 Lateral Detector lift will not move after going to max SID using the Emergency Backout button on the lift cover because the lift hit maximum (Max) SID limit sw…
- Firewall is broadcasting DHCP addresses
- Cooling Failure; Shut System down and call Service is displayed on the Innova Image monitor
- No gantry motion is reported by the customer.